Table 159 SNMP System Traps (continued)
OPTION
OBJECT LABEL
poe
zyPoePowerPortOverload
(For PoE
zyPoePowerPortShortCircuit 1.3.6.1.4.1.890.1.15.3.59.4.2
models only)
zyPoePowerPortOverSyste
mBudget
zyPoePowerPortOverloadRe
covered
zyPoePowerPortShortCircuit
Recovered
zyPoePowerPortOverSyste
mBudgetRecovered
temperature
zyHwMonitorTemperatureO
utOfRange
zyHwMonitorTemperatureO
utOfRangeRecovered
voltage
zyHwMonitorPowerSupplyV
oltageOutOfRange
zyHwMonitorPowerSupplyV
oltageOutOfRangeRecovere
d
reset
zySysMgmtUncontrolledSys
temReset
zySysMgmtControlledSyste
mReset
zySysMgmtBootImageInco
nsistence
RebootEvent
timesync
zyDateTimeTrapTimeServer
NotReachable
zyDateTimeTrapTimeServer
NotReachableRecovered
intrusionlock
zyPortIntrusionLock
loopguard
zyLoopGuardLoopDetect
Chapter 38 Access Control
OBJECT ID
1.3.6.1.4.1.890.1.15.3.59.4.1
1.3.6.1.4.1.890.1.15.3.59.4.3
1.3.6.1.4.1.890.1.15.3.59.4.5
1.3.6.1.4.1.890.1.15.3.59.4.6
1.3.6.1.4.1.890.1.15.3.59.4.7
1.3.6.1.4.1.890.1.15.3.26.2.2
1.3.6.1.4.1.890.1.15.3.26.2.7
1.3.6.1.4.1.890.1.15.3.26.2.3
1.3.6.1.4.1.890.1.15.3.26.2.8
1.3.6.1.4.1.890.1.15.3.49.2.1
1.3.6.1.4.1.890.1.15.3.49.2.2
1.3.6.1.4.1.890.1.15.3.49.2.3
1.3.6.1.4.1.890.1.5.1.1.2
1.3.6.1.4.1.890.1.15.3.82.3.1
1.3.6.1.4.1.890.1.15.3.82.3.2
1.3.6.1.4.1.890.1.15.3.61.3.2
1.3.6.1.4.1.890.1.15.3.45.2.1
GS2210 Series User's Guide
322
DESCRIPTION
This trap is sent when the port is turned
off to supply power due to overloading.
This trap is sent when the port is turned
off to supply power due to short circuit.
This trap is sent when the port is turned
off to supply power because the
requested power exceeds the total PoE
power budget on the Switch.
This trap is sent when the port is turned
on to recover from an overloaded state.
This trap is sent when the port is turned
on to recover from a short circuit.
This trap is sent when the port is turned
on to recover from an over system
budget.
This trap is sent when the temperature
goes above or below the normal
operating range.
This trap is sent when the temperature is
recovered from the out of range to
normal operating range.
This trap is sent when the voltage goes
above or below the normal operating
range.
This trap is sent when the power supply
voltage is recovered from the out of
range to normal operating range.
This trap is sent when the Switch
automatically resets.
This trap is sent when the Switch resets
by an administrator through a
management interface.
This trap is sent when the index number
of image which is loaded when the Switch
starts up is different from what is
specified via the CLI.
This trap is sent when the Switch reboots
by an administrator through a
management interface.
This trap is sent when the Switch's date
and time is not manually entered or the
specified time server is not reachable.
This trap is sent when the Switch's real
time clock is up to date.
This trap is sent when intrusion lock
occurs on a port.
This trap is sent when loopguard shuts
down a port.