Command And Response Table For Sis Commands - Extron electronics FOX Matrix 3200 User Manual

Configurable fiber optic digital matrix switchers
Table of Contents

Advertisement

Command and Response Table for SIS Commands

Symbol Definitions
]
= CR/LF (carriage return/line feed) (hex 0D 0A )
}
= Carriage return (no line feed, hex 0D )
|
= Pipe (can be used interchangeably with the
= Space character
E
= Escape key (hex 1B )
W
= Can be used interchangeably with the
X!
= Input number (for tie)
X@
= Output number
X#
= Mute
X$
= SFP or reclockable output number
X%
= Output reclocking rate
X^
= Laser control
X&
= Global preset #
X*
= Room number (for room presets)
NOTE: A Room is a subset of operator‑selected outputs that relate to each other. The FOX matrix switcher supports up to 10 rooms, each
of which can consist of 1 to 16 outputs.
X(
= Name
NOTE: The following characters are invalid or not recommended in the name: ~ , @ = ' [ ] { } < > ' " ; : | \ and ? .
X1)
= Room preset number
NOTE: A Room preset is a stored configuration with all outputs in a single room. A retrieved room preset becomes the current configuration.
X1!
= Connection status
X1@
= Group number (for I/O grouping)
X1#
= Input number (for other than tie)
X1$
= Lock mode status
X1%
= Number (quantity) of inputs
X1^
= Number (quantity) of outputs
X1&
= Board installed
X1*
= I/O board slot number
X1(
= Transceiver module installed
X2)
= Transceiver module number
X2!
= Vendor/manufacturer name
X2@
= Transmit output power in milliwatts
X2#
= Receive optical power in milliwatts
X2$
= SFP temperature
X2%
= Firmware version number to second decimal place (x.xx)
X2^
= Verbose firmware version‑description‑upload date/time. See the Query controller firmware version (verbose) command on
X2&
= Voltage
X2*
= Temperature
X2(
= Fan speed
* Legacy board, no longer manufactured, identified for completeness only
}
character)
E
character
00 – 32 (FOX Matrix 3200) or 72 (FOX Matrix 7200) ( 00 = untied)
01 – 32 (FOX Matrix 3200) or 72 (FOX Matrix 7200)
0 = not muted
00 – 32 or 72 (00 = global [SFP only])
00 = auto (default)
0 = disable
00 – 32 (3200) or 72 (7200) ( 00 = current configuration for view only)
01 – 10 maximum (each can have up to 10 presets (
Up to 12 characters for input and output names and global and room preset names
Upper‑ and lower‑case alphanumeric characters and _ / and spaces are valid.
01 – 10 maximum
0 = no input connected
1 (group 1) through 4 (group 4) (or 0 = no group)
01 – 32 (FOX Matrix 3200) or 72 (FOX Matrix 7200)
0 = unlocked
8 , 16 , 24 , 32 , 40 , 48 , 56 , 64 , or 72
8 , 16 , 24 , 32 , 40 , 48 , 56 , 64 , or 72
0 = No board installed
1 = Non‑reclocking multimode board*
2 = Non‑reclocking singlemode board*
3 = 3G, SDI, HD‑SDI board
1 – 9 (FOX Matrix 7200) or 1 – 4 (FOX Matrix 3200)
0 = No module installed
1 = Non‑pathological multimode module
2 = Non‑pathological singlemode module
01 – 72 (or maximum number of transceiver modules for your configuration)
Degrees Celsius
Positive or negative voltage and magnitude
Degrees Fahrenheit
In revolutions per minute (RPM)
FOX Matrix 3200 and 7200 Switchers • Programming Guide
1 = muted
01 = bypass
1 = enable
2 = automatic
X1)
) assigned)
1 = input connected
1 = locked
4 = Non‑pathological multimode board
5 = Non‑pathological singlemode board
6 = Pathological singlemode board
x = Unknown board or mix of transceivers
3 = 3G‑SDI, HD‑SDI, SD‑SDI module
4 = Pathological singlemode module
page