VII. ERROR CODES

During operation, the RCVDS05 can display several error codes on its seven
segment display.
The F error codes ask for an intervention by the operator himself.
The E error codes ask for a service intervention by your dealer. Call your BARCO
dealer for technical assistance.
68
Error F1 : expansion module is not in correct slot.
Power down the RCVDS05 and remove the expan-
sion module. Re-insert the expansion module in the
last free slot of the RCVDS05 so that all input mod-
ules are located to the left of the expansion module.
Error E1 : I²C error, call for technical assistance.
Error E2 : I²C error, PCF8574 fails on communication
module, call for technical assistance.
Error E3 : I²C error, Controller eeprom (24C16), call for
technical assistance.
Error E4 : I²C error audioprocessor, call for technical
assistance (TDA8425).
Error E5 : I²C error, PCF8574 fails on the audiomodule,
call for technical assistance.