B. COMMUNICATION INTERFACE MODULE
order number : 98 28010
When the RCVDS05's are linked or the optional IR remote receiver will be used or your
RCVDS05 will be controlled by a central computer, a communication module must be
installed in the slot near the output module.
For typical configurations see Installation.
Connections :
* The female D9 Sub-D connector, indicated as "to host" must be connected to
the communication port RS232 on the computer.
* the male D9 Sub-D connector, indicated as "to next device" must be connected to
:
- to next RCVDS05 in the link (see installation)
or
- the optional IR remote receiver unit.
26
SPECIAL MODULES
From
central computer
Mode switch
"BARCO" or "RS232"
To next RCVDS05
or
IR receiver unit
98 28010
R5975765 RCVDS05 020997