BLOCK TRANSFER EEPROM to PC
Send all the used bytes in the EEPROM to the PC (168 bytes)
PC to RCVDS :
RCVDS to PC : ACK
Block returned :1st byte = data addr 0 EEPROM
Meaning of these bytes
byte
0 - 7
8 - 15 contents source 2
16 - 23 contents source 3
24 - 31 contents source 4
.
.
.
160-167 contents source 20
With for each source in this order (contents of all the sources)
byte 0
1
2
3
4
5
6
7
source type : the same as the values returned in the command READ_SOURCE
(01 = video, 2 = SVHS, 4 = RGsB, ..., 7FH = expansion module and 7EH = no
module inserted.
Example : the 17 th receaved byte (if we give no. 0 to the first received byte (EEPROM
address 0) contains the tint of source 2.
R5975765 RCVDS05 020997
STX OFFS ADR 72H FFH FFH FFH FFH CHKS
ADR 72H FFH FFH FFH FFH CHKS
then 168 bytes (block) are sent
CHKS after the 168 bytes.
2 nd byte = data addr 1 EEPROM
....
168st byte = data addr 167 EEPROM
contents source 1
.
.
.
volume (22H .. 3FH)
tint (0 .. 7FH)
saturation (0 .. 7FH)
sharpness (E0H .. E3H)
source type
reserved
reserved
reserved
72H