Barco R9841770 Installation Manual
Barco R9841770 Installation Manual

Barco R9841770 Installation Manual

Lamp kit for iq/sim4 projectors
Hide thumbs Also See for R9841770:

Advertisement

Quick Links

R5976375/03
23/06/2004
Lamp Kit for iQ/SIM4 Projectors
Installation Manual
R9841770 - R9841771
R9841100 - R9841111
R9841760 - R9841761

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the R9841770 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Barco R9841770

  • Page 1 Lamp Kit for iQ/SIM4 Projectors Installation Manual R9841770 - R9841771 R9841100 - R9841111 R9841760 - R9841761 R5976375/03 23/06/2004...
  • Page 2 Barco nv Intelligent Displays Noordlaan 5, 8520 Kuurne Phone: +32 56.36.82.11 Fax: +32 56.35.86.51 E-mail: presentations.bid@barco.com Visit us at the web: www.barco.com Printed in Belgium...
  • Page 3: Federal Communications Commission (Fcc) Statement

    Copyright © All rights reserved. No part of this document may be copied, reproduced or translated. It shall not otherwise be recorded, transmitted or stored in a retrieval system without the prior written consent of Barco. Federal Communications Commission (FCC Statement) This equipment has been tested and found to comply with the limits for a class A digital device, pursuant to Part 15 of the FCC rules.
  • Page 5: Safety Guidelines

    Lamp Runtime Warning: Do not exceed the indicated maximum total lifetime of the lamp for safe operation in normal power mode. Do not use it longer ! Always replace the lamp with the BARCO lamp kit. R5976375 LAMP KIT FOR IQ/SIM4 PROJECTORS 23/06/2004...
  • Page 6 1. Safety R5976375 LAMP KIT FOR IQ/SIM4 PROJECTORS 23/06/2004...
  • Page 7: Kit Content

    Depending on the Kitnumber ordered the kit may contain 1 or 2 lamps, the lamp power may also differ according to the type of Projector. Kitnumber Description Quantity Manual IQ200 R9841771 120 W Lamp R5976375 R9841770 120 W Lamp R5976375 IQ300/MGP10/SIM4 R9841111 200 W Lamp R5976375 R9841100 200 W Lamp R5976375...
  • Page 8 2. Kit Content R5976375 LAMP KIT FOR IQ/SIM4 PROJECTORS 23/06/2004...
  • Page 9 3. Replacement procedure in case of an iQ Projector 3. REPLACEMENT PROCEDURE IN CASE OF AN IQ PROJECTOR Overview • Reset lamp runtime • Access to the lamp unit(s) in the iQ projector • Removing the lamp unit(s) • Mounting the Lamp Unit •...
  • Page 10 3. Replacement procedure in case of an iQ Projector ARNING Lamp runtime reset as well as the lamp replacement can only be done by a Barco authorized technician. 3.2 Access to the lamp unit(s) in the iQ projector 3.2.1 Removing the back cover...
  • Page 11: Necessary Tools

    3. Replacement procedure in case of an iQ Projector 3.3 Removing the lamp unit(s) 3.3.1 Removing the lamp unit(s) What has to be done ? The lamp power connection has to be disconnected. The lamp unit has to be removed. Perform the procedure for both lamps if necessary.
  • Page 12 3. Replacement procedure in case of an iQ Projector Image 3-9 Image 3-8 unlocking lamp 1 & lamp 2 Image 3-10 Lamp 1 removed 3.4 Mounting the Lamp Unit 3.4.1 Mounting the lamp unit(s) What has to be done ? The lamp has to be mounted The lamp has to be connected.
  • Page 13: Mounting The Cover

    3. Replacement procedure in case of an iQ Projector Necessary tools No tools. Necessary parts No parts. How to mount the lamp unit ? 1. Place carefully the lamp against the frame 2. Push the lamp inwards and turn the lamp locking handle over to lock the lamp (image 3-11) 3.
  • Page 14 3. Replacement procedure in case of an iQ Projector 3.6 Cleaning How to clean the dustfilters ? 1. Place the projector so as to access easily the filter to be cleaned 2. Push the handle downwards to unlock the filter. (image 3-14) 3.
  • Page 15 3. Replacement procedure in case of an iQ Projector If the airflow is falling under a predetermined treshold value a warning will be displayed on the screen. Image 3-19 At that time it is strongly recommended to replace or clean the dustfilter under the X-cube. Failing to do so, will strongly reduce the lifetime of the LCD’s and the analyzers.
  • Page 16 3. Replacement procedure in case of an iQ Projector R5976375 LAMP KIT FOR IQ/SIM4 PROJECTORS 23/06/2004...
  • Page 17: Lamp Replacement

    4. Replacement in case of a SIM 4 projector 4. REPLACEMENT IN CASE OF A SIM 4 PROJECTOR 4.1 Lamp replacement AUTION Do not touch the cover glass with your fingers. If the lamp is touched, finger prints can be removed by cleaning the lamp with alcohol.
  • Page 18 4. Replacement in case of a SIM 4 projector Image 4-1 Location of side door screw Image 4-2 side door open Image 4-3 Lamp disconnected LOCK UNLOCK Image 4-4 Lamp locking handle R5976375 LAMP KIT FOR IQ/SIM4 PROJECTORS 23/06/2004...
  • Page 19 4. Replacement in case of a SIM 4 projector Image 4-5 Lamp removed When replacing the lamp it is strongly recommended to check and clean (or replace if necessary) the dustfil- ters. R5976375 LAMP KIT FOR IQ/SIM4 PROJECTORS 23/06/2004...
  • Page 20 4. Replacement in case of a SIM 4 projector R5976375 LAMP KIT FOR IQ/SIM4 PROJECTORS 23/06/2004...
  • Page 21 Index INDEX mounting removing access runtime reset iQ Content Menu cover 6, 9 Lamp menu mounting reset runtime removing replacement 5, 13 Filters cleaning right side sim4 Runtime reset content safety guidelines lamp 5–8 access R5976375 LAMP KIT FOR IQ/SIM4 PROJECTORS 23/06/2004...
  • Page 22 Index R5976375 LAMP KIT FOR IQ/SIM4 PROJECTORS 23/06/2004...
  • Page 23: Revision Sheet

    Revision Sheet Barco nv Intelligent Displays Noordlaan 5, 8520 Kuurne Phone: +32 56.36.82.11, Fax: +32 56.35.86.51 E-mail: presentations.bid@barco.com, Web: www.barco.com From: Date: Please correct the following points in this documentation (R5976375/03): page wrong correct R5976375 L Q/SIM4 P 23/06/2004 IT FOR I...

This manual is also suitable for:

R9841771R9841100R9841111R9841760R9841761

Table of Contents