Mbus Client Exec - THOMSON TG576 v7 Reference Manual

Residential dsl gateway
Hide thumbs Also See for TG576 v7:
Table of Contents

Advertisement

mbus client exec

Execute mbus command
SYNTAX:
mbus client exec
where:
cmd
param
value
gettype
depth
processcmd
onerrorrollback
usecallback
filter
486
cmd = <{getpath|getcount|getnames|getvalues|
setvalue|addobject|deleteobject|subscribe|
unsubscribe|getaccessrights|setaccessrights}>
[param = <quoted string]>
[value = <quoted string]>
[gettype = <{parameter|path|object}]>
[depth = <number]>
[processcmd = <{enabled|disabled}]>
[onerrorrollback = <{enabled|disabled}]>
[usecallback = <{enabled|disabled}]>
[filter = <quoted string]>
[path = <quoted string]>
[flags = <[+/-]flag[+/-flag...]{indexpath
objidpath keystrpath uncommitted xref_localidx
xref_objid xref_keypath exact_depth
applyonparamsapplyrecursive typetreepath
non_persistent}]>
[accesslist = <quoted string]>
[action = <[+/-]flag[+/-flag...]{read write
attrchg}]>
[modifier = <{add|delete|allow_only|
allow_except}]>
[replytype = <{getallowed|getdisallowed|
getasconfigured}]>
[attribute = <{ar_archg|ar_read|ar_write|
param_cached|param_eventable|object_dynamic}]>
Mbus command name
Parameter name
Parameter value to set
Get type elements (default=param)
Number of levels to recurse, default=-1 (all)
Process SET_VALUE command flag
(default=enabled)
on error rollback flag (default=enabled)
Use result callback function (default=enabled)
The filter should be formatted as '(operator
operand operand)'. Possible operators are ==, !
mbus Commands
REQUIRED
OPTIONAL
OPTIONAL
OPTIONAL
OPTIONAL
OPTIONAL
OPTIONAL
OPTIONAL
OPTIONAL
E-DOC-CTC-20071119-0014 v1.0