Table 3-1 Thermostat Status Field Descriptions; Figure - Proliphix Professional NT100e/h Configuration Manual

Professional series network thermostat
Table of Contents

Advertisement

CHAPTER 3: Configuring the Thermostat Using the TMI
Use
Settings, and Alarm Status fields.

Table 3-1 Thermostat Status Field Descriptions

Field
Temperature
Zone Temperature
Local (Temperature)
RS #1
RS #2
Relative Humidity
(NT150e/h and
NT160e/h only)
Override
3-10
Table 3-1
to configure the Temperature status, Schedule Settings, HVAC
Description
Displays the current temperature of the local sensor if temperature averaging
is disabled.
Average temperature of any combination of Local, Remote Sensor #1 (RS
#1) or Remote Sensor #2 (RS #2) if temperature averaging is enabled. (See
Advanced Settings Page (page
In a range of -30
Displays the current temperature of the local sensor. This field is disabled if
the local thermostat sensor is not included in temperature averaging. This
field is not visible on the NT100e/h thermostat.
In a range of 45
Displays the current temperature of Remote Sensor #1 if this remote thermal
sensor is installed and enabled. This field is disabled if RS #1 is not included
in temperature averaging.This field is not applicable on the NT100e/h
thermostat. (See
In a range of -30
Displays the current temperature of Remote Sensor #2 if this remote thermal
sensor is installed and enabled. This field is disabled if RS #2 is not included
in temperature averaging.This field is not applicable on the NT100e/h
thermostat. (See
In a range of -30
Displays the relative humidity for the thermostat. The NT150e/h and
NT160e/h thermostat is capable of measuring the relative humidity of the
local air. The relative humidity is sampled once per minute and has an
accuracy of ±3.0%. The reading includes temperature compensation for
temperature readings significantly different from 77°F. This field is only
applicable on the NT150e/h and NT160e/h thermostat.
In a range of 10% to 90% RH
Displays whether Heat or Cool Settings are different from the current
scheduled settings. Changes made to either the Heat or Cool Settings
(which force an override) remain at those settings until the next scheduled
Period change. At the Period change, the settings for either/both heat or cool
follow the schedule. (See
Override
Professional Series Network Thermostat Configuration Guide, Release 3.0
Beta Draft Confidential
3-35).)
°
°
°
°
F(-34
C) to 199
F(95
°
°
°
°
F(7
C) to 95
F(35
C)
Advanced Settings Page (page
°
°
°
°
F(-34
C) to 199
F(95
Advanced Settings Page (page
°
°
°
°
F(-34
C) to 199
F(95
Schedule Settings (page
Part No. 600-01000-200, Rev. 2
C)
3-35).)
C)
3-35).)
C)
3-11).)