Table 3-6 Advanced Settings Fields - HVAC Fuel Burner Field Descriptions

Field
HVAC System Type
If Your HVAC System is a Fuel Burner
Heat Control
nd
2
Professional Series Network Thermostat Configuration Guide, Release 3.0
Part No. 600-01000-200, Rev. 2
Table 3-6
to configure the Advanced Settings for a parameters.
Stage Offset
Description
Select the type of HVAC system, either Fuel Burner (default) or
Heat Pump HVAC systems as follows:
Fuel Burner (default) – The HVAC system burns fossil
fuels (e.g. gas or oil). Typically the system includes either an
oil or gas fired boiler or furnace. See
page 3-36
and continue with
Burner (page
3-37).
Heat Pump – Specifies that the HVAC system is based on
an electric compressor. See
continue with
If Your HVAC System is a Heat Pump (page
3-38).
Note: When selecting between either Fuel Burner or Heat
Pump or between Heat Pump and Fuel Burner, the HVAC
Mode must be set to Off prior to selecting the opposite setting.
See the
Status & Control Page (page
Select the HVAC control for this thermostat. This parameter
describes the thermostat capability to control a single stage or
dual stage heating system. The thermostat can also be disabled
from controlling a heating system and instead operate as a
cool-only thermostat. (See
Cool Control (page
Disable – No heating system exists. (A/C only thermostat.)
1H – Enables the heating system as a standard single stage
system.
2H (default) – Enables the heating system as a dual stage
system.
Specify the second stage heat set point temperature referenced to
the first stage heat set point temperature. This parameter is only
enabled when 2H
Heat Control
disabled. (e.g. If the first stage temperature set point is set to
70°F, and this parameter were set to -3°F, the second stage heat
would activate at or below 67°F). Temperatures include:
0, -2, -3, -4, -5, -6 °F (0, -1.0, -1.5, -2.0, -2.5, -3.0 °C) – Second
stage heat temperature offset from first stage heat set point
temperature.
Advanced Settings Page
Figure 3-15 on
If Your HVAC System is a Fuel
Figure 3-14 on page 3-35
and
3-9).
3-38).)
is selected, otherwise it is
3-37