Connecting the Alarm Output Signal
Connect the signal cable of the alarm output device to the RELAY 1/2 terminal on the DVR's rear
panel.
1.
2.
3.
4.
Communication Port Connection
www.honeywell.com/security
Push the Alarm IN and GND terminals' bottom side inwards with a sharp tipped tool such
as a screwdriver.
While pushing inwards, insert one end of the alarm signal cable into the hole of Alarm IN
terminal.
While pushing inwards, insert one end of the ground cable into the hole of the GND
terminal.
To check proper insertion of the cable, stop pushing the terminal's bottom side inwards
and gently pull the cable and test whether it disconnects.
Note
To disconnect a cable, push the bottom side of the terminal inwards and pull out
the cable.
Push the NO/NC/COM terminal's bottom side inwards with a sharp tipped tool such as a
screwdriver.
While pushing inwards, insert one end of the alarm signal cable into the desired terminal of
NO or NC.
•
NO (Normal Open): Normally Open but switching to Close if an alarm out occurs.
•
COM: Insert the grounding wire.
•
NC (Normal Close): Normally Close but switching to Open if an alarm out occurs.
Insert the ground signal wire into the hole of the COM port.
To check proper insertion of the cable, stop pushing the terminal's bottom side inwards
and gently pull the cable and test whether it disconnects.
Note
To disconnect a cable, push the bottom side of the terminal inwards and pull out
the cable.
Figure 2-4
Communication Port Connections on the Rear Panel