Alarm Sensors; Connecting An Alarm Sensor; Inputs For Sensors; Configuration Using View Software - Honeywell Rapid Eye Installation Manual

Multi-media digital video recorder
Hide thumbs Also See for Rapid Eye:
Table of Contents

Advertisement

Alarm Sensors

Connecting an Alarm Sensor

Inputs for Sensors

Configuration Using View Software

Document 800-02607V3 Rev A
11/09
To connect alarm-type hardware to a Multi-Media DVR, use hookup wire in the 20-gauge
range.
Tools you may need:
A slot screwdriver (supplied). The screws are smaller than those for a 1/8 inch
screwdriver.
A wire stripper.
1.
From the alarm wire tips, strip approximately 0.6 cm (1/4 inch) of insulation.
2.
Insert each alarm wire into the screw-type, terminal connector on the ALARM terminal
strip: one wire to the numbered terminal connection and the other wire to ground.
Caution
To avoid short-circuits, ensure that bare wire is not visible at the rear panel.
Using View, start a Maintenance session for the Rapid Eye site. Wait until the System
1.
Operational message appears. Click the Events tab. More tabs are displayed.
2.
Click the Inputs tab.
3.
Enter the name of an input in its Input box. You have the option of identifying inputs
that are not in use, such as input 7 and input 8 (see
4.
You have the option of monitoring the activation of inputs and their deactivation by
selecting Log and Alarm, as needed.
5.
By default, alarm/control inputs are configured as NO. Click NC or EOL, as needed.
Rapid Eye™ Multi-Media DVR Installation Guide
Figure
5-4).
57

Advertisement

Table of Contents
loading