Code 93 Set Length 1 - Datalogic PowerScan PD9530 Product Reference Manual

Powerscan 9500 family industrial corded handheld area imager bar code reader
Hide thumbs Also See for PowerScan PD9530:
Table of Contents

Advertisement

Code 93 Set Length 1

Specifies one of the bar code lengths for
is the minimum label length if in
length if in
ters only. The length can be set from 01 to 50 characters.
Table 20
detailed instructions on setting this feature.
Table 20. Code 93 Length 1 Setting Examples
STEP
ACTION
1
Desired Setting
2
Scan ENTER/EXIT PROGRAMMING MODE
3
Scan SELECT CODE 93 LENGTH 1 SETTING
Scan Two Characters From
4
Appendix D, Keypad
5
Scan ENTER/EXIT PROGRAMMING MODE
$CC9L1
Select Code 93 Set Length 1 Setting
Make a mistake? Scan the CANCEL bar code to abort
and not save the entry string. You can then start
again at the beginning.
Product Reference Guide
Fixed Length
Mode. Length includes the bar code's data charac-
provides some examples for setting Length 1. See
EXAMPLES
01 Characters
'0' and '1'
01 = Length 1 is 1 Character
DEFAULT
Enter/Exit Programming Mode
Code 93 Length
Variable Length
Mode, or the first fixed
07 Characters
15 Characters
'0' and '7'
'1' and '5'
~
CANCEL
Control. Length 1
page 267
for
50 Characters
'5' AND '0'
161

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Powerscan pbt9500Powerscan pm9500

Table of Contents