References
Table 38
STEP
ACTION
Scan the ENTER/EXIT bar
1.
code
Determine placement of
the Label ID characters
BEFORE or AFTER with
regard to scanned data
2.
using Label ID
Control, starting on page
56
Scan the bar code selecting
the symbology type you
wish to designate label ID
characters for using Label
3.
ID Symbology Selection −
1D Symbologies, starting
on page 57 .
Custom Label ID example
4.
(desired characters):
Find hex equivalents from
the ASCII Chart (inside
back cover), then scan in
these digits/characters
using the bar codes in the
section: Keypad, starting
on page 323 . If you make
5.
a mistake before the last
character, scan the CANCEL
bar code to abort and not
save the entry string. You
can then start again at the
beginning.
Scan the ENTER/EXIT bar
6.
code
Scan the ENTER/EXIT bar
7.
code once again
Result:
276
. Label ID Examples
EXAMPLES
Enable as Prefix Enable as Suffix Enable as Prefix
DataBar
Omnidirectional
D B *
44 42 2A
DB*[bar code
data]
(Scanner enters Programming Mode)
Interleaved 2 of
Code 39
5
= C 3
+
3D 43 33
2B
(Scanner exits Label ID entry)
(Scanner exits Programming Mode)
[bar code
+[bar code data]
data]=C3
PowerScan™ PD9530/PBT9500/PM9500
Enable as Suffix
Code 32
P H
50 48
[bar code data]PH