Introduction
The BC9xx0™ Base Station/Charger
The BC9xx0 base station, when paired with one or more PowerScan™ 9500
readers, builds a Cordless Reading System for the collection, decoding and
transmission of bar code data. It can be connected to a Host PC via RS-232,
USB, or KBD Wedge, and is suited for single-cradle layouts. The BC91x0
models also provide a spare battery charger slot.
The label on the cradle contains LED indicators and a multi-function button.
When the button is pressed for less than 5 seconds, the cradle will transmit a
"broadcast" message." When the broadcast is sent, all properly configured
scanners (Radio RX Timeout set to keep the radio "awake") that are linked to
that base and within radio range coverage will emit a beep and blink within 5
seconds. This functionality is useful to:
When the button is pressed for longer than 5
seconds, all paired scanners will be unpaired.
The LEDs signal the BC9xx0-BT status, as shown in
Table 1. LED Status
LED
Aux
Host
Reader
Spare
(BC91x0
models
only)
Radio
Ethernet
(Ethernet
models
only)
See
"Base Station Indications (Cordless Models ONLY)" on page 304
specific details on the LEDs.
4
verify which scanners are linked to a certain
base station
detect a scanner forgotten somewhere
STATUS
Yellow On = BC9xx0 is powered through an external power supply.
Yellow On = BC9xx0 is powered by the Host.
Green On = the reader battery is completely charged.
Red On = the reader battery is charging.
Orange Blinking = reader battery fault - replace battery.
Red / Green Alternatively Blinking = charging error - see "
on page 304
.
Off = reader not in the cradle or not properly inserted.
Green On = the spare battery is completely charged.
Orange Blinking = spare battery fault - replace spare battery.
Red/Green Alternatively Blinking = charging error - see "
page 304
.
Off = no spare battery in the housing or battery not fully inserted.
Yellow Blinking = radio activity.
Green Blinking = Ethernet activity.
Table 1 on page
Error Codes" on
PowerScan™ PD9530/PBT9500/PM9500
4.
Error Codes"
for more