Advanced Formatting: User Label Edit; Case Conversion; Character Conversion - Datalogic PowerScan PD9530 Product Reference Manual

Powerscan 9500 family industrial corded handheld area imager bar code reader
Hide thumbs Also See for PowerScan PD9530:
Table of Contents

Advertisement

Advanced Formatting: User Label Edit

Advanced formatting is available to create user label edit scripts. See the
Datalogic Aladdin configuration application or contact Technical Support.

Case Conversion

This feature allows conversion of the case of all alphabetic characters to
upper or lower case.
DEFAULT
$CLFCA01(CR)
Case Conversion = Convert to upper case

Character Conversion

Character conversion is an eight byte configuration item. The eight bytes are
4 character pairs represented in hexadecimal ASCII values. The first charac-
ter in the pair is the character that will be converted. The second character in
the pair is the character to convert to. If the character to convert in a pair is
FF, then no conversion is done.
Product Reference Guide
Case conversion affects ONLY scanned bar code data, and does not affect
Label ID, Prefix, Suffix, or other appended data.
If less than the expected string of 16 characters are selected, scan the
ENTER/EXIT bar code twice to accept the selections and exit Programming
Mode.
0xFFFFFFFFFFFFFFFF
DEFAULT
(No character conversion)
$CLFCA00(CR)
Case Conversion = Disable (no case conversion)
$CLFCA02(CR)
Case Conversion = Convert to lower case
$CLFCH
Configure Character Conversion
Label ID