Enter/Exit Programming Mode

STAR Radio Transmit Mode

Specifies the transmission protocol for Star communications.
Options are:
DEFAULT
ACK when sent to host
236
ACK from cradle to scanner — signals a good transmission as soon as
the Base Station receives a label
ACK when sent to host — scanner signals a good transmission as soon
as the Base Station has sent the label to the host
ACK from host — scanner signals a good transmission as soon as the
Base Station has sent the label to the host and host has replied with an
acknowledge message.
ACK from host works only for RS-232 or USB-COM interfaces with
ACK/NACK disabled. If ACK from host is configured with any other
interface conditions, it works like ACK when sent to host. See
"Message Formatting"
For this feature to be operational, the scanner must be set to
Ignore Host Commands (see
The Base Station can receive a host message only if Host Com-
mands Obey/Ignore (page 23) is set to Ignore.
ACK from cradle
ACK from host
on page 293 for details.