The following options apply to the Industrial 2 of 5 symbology.

Industrial 2 of 5 Enable/Disable

Enables/Disables ability of reader to decode Industrial 2 of 5 labels.
DEFAULT
$CU2EN01(CR)
Industrial 2 of 5 = Enable

Industrial 2 of 5 Check Character Calculation

Enables/Disables calculation and verification of an optional Industrial 2 of 5
check character.
DEFAULT
$CU2CC01(CR)
Industrial 2 of 5 Check Character Calculation = Enable
Product Reference Guide

INDUSTRIAL 2 OF 5

$CU2EN00(CR)
$CU2CC00(CR)
Industrial 2 of 5 Check Character Calculation = Disable
Enter/Exit Programming Mode
Industrial 2 of 5 = Disable