Msi Check Character Calculation; Msi Check Character Transmission - Datalogic PowerScan PD9530 Product Reference Manual

Powerscan 9500 family industrial corded handheld area imager bar code reader
Hide thumbs Also See for PowerScan PD9530:
Table of Contents

Advertisement

Enter/Exit Programming Mode

MSI Check Character Calculation

Enables/Disables calculation and verification of an optional MSI check char-
acter.
$CMSCC01(CR)
MSI Check Character Calculation = Enable Mod10
$CMSCC03(CR)
MSI Check Character Calculation = Enable Mod10/10

MSI Check Character Transmission

Enables/disables transmission of an MSI check character.
$CMSCT01(CR)
MSI Check Character Transmission = Enable
164
$CMSCC00(CR)
MSI Check Character Calculation = Disable
DEFAULT
$CMSCC02(CR)
MSI Check Character Calculation = Enable Mod11/10
$CMSCT00(CR)
MSI Check Character Transmission = Disable
DEFAULT