• CALIBRATE LITELOC
The LiteLoc calibration process must be run to calibrate the LiteLoc sensor on all model types. "Constant
Intensity" mode cannot operate correctly if the calibration has not been performed. The calibration must be
done in Dual Lamp mode, after the lamps have warmed up for at least 5 minutes.
for the duration of the calibration, and will automatically open again when the calibration is complete.
• FREEZE IMAGE DURING AUTO SETUP
*Available with 3D option only.
If selected, this will hide temporary image artifacts that may appear during the auto setup procedure.
OPTION CARD SETTINGS - S
Allows adjustment of any settings specific to each option card that is currently installed in the projector.
IRIS - S
UBMENU
Refer to Image Settings>Advanced Image Settings
3.9

Lamp Menu

LAMP OPERATION
Select the operational mode to be assigned to the
lamp(s) from the Lamp Operation drop-down list. If
a lamp fails to strike on the first attempt, you can
attempt upto 3 more strikes.
The Lamp Operation modes are:
• Lamp 1 single lamp use or Lamp 2 single lamp
use modes will only use the lamp specified. If the
selected lamp will not strike, then the projector
will not turn on. If the "Single Lamp Switch on
fail" option is enabled, the projector will always
attempt to turn on the selected lamp first, but if that lamp fails all attempts to strike, it will cause a switch to
the other lamp. This option is not enabled for DLV models, which are restricted to operate in Dual Lamp Use
mode only.
• Dual Lamp Use mode will use both lamps together. After 3 failed attempts to stay in Dual Lamp Use mode,
the projector will switch to Single Lamp operation; however, the user-selected mode remains as Dual Lamp
Mode.
• Auto-Select a Single Lamp mode will choose the best lamp for single lamp operation. The lamp selection is
based on:
• The lamp that will be the fastest to turn on (a lamp can be chosen if it is currently on, or if it has been off
for at least the minimum hot re-strike period)
• The lamp that has been least used (determined by the lamp voltage, which increases as the lamp ages)
• The lamp with the fewest hours (this attempts to balance the lifetime of the two lamps)
In Auto-Select Single Lamp mode, a failure of a lamp to strike will cause a switch to the other lamp. This
option is not enabled for DLV models, which are restricted to operate in Dual Lamp Use mode only.
Single Lamp mode, available for DLV models only.
Mirage M Series User Manual
020-100575-02 Rev. 1 (11-2010)
UBMENU
Section 3: Operation
The shutter will close
NOTE:
F
3-37 L
M
IGURE
AMP
ENU
3-49

Advertisement

Table of Contents
loading

Table of Contents