Status Indicator Lights - Xantrex GT5.0-NA-240 Owner's Manual

Grid tie solar inverter
Table of Contents

Advertisement

Status Indicator Lights

975-0334-01-01
The GT Inverter has two status indicator lights (LEDs) located below the front
panel LCD (Figure 5-2). These LEDs indicate the inverter's status (Table 5-11)
and assist in troubleshooting the performance of the unit.
Only one indicator light will be lit at any time.
Table 5-11 Status Indicator LEDs
LED on
Means
GREEN
GT Inverter is on (DC voltage and AC voltage are qualified and the
protection timer has finished) and delivering power. No action
required. Turns off when a fault state is detected.
RED
Ground fault condition detected.
Check for any fault messages on the display (see Table 5-8), and refer
also to Table 6-1, "Troubleshooting the GT Inverter" on page 6–9 to
resolve the fault condition.
Green LED
Grid Tie Solar Inverter
Figure 5-2 Status Indicator Lights
Status Indicator Lights
Red LED
5–11