Freedom HFS IC Owners Guide.book Page 28 Friday, September 11, 2015 2:54 PM

Invert Power Derating vs. Ambient Temperature

If the unit is in inverter mode and in elevated ambient temperature
above 25 °C, you will have to reduce power draw according to the
following chart to avoid over-temperature shutdown.
watts
@12.5 volts
1000
900
850
800
750
25
28
Freedom HFS 1055
30°C
900 watts
°C
30
35
40
45
50
watts
2000
@12.5 volts
1800
1600
1400
1200
1000
25
30
Freedom HFS 2055
1900 watts
1800 watts
1500 watts
°C
35
40
45
50