Front Panel Display Screens And What They Mean; Startup Mode - Xantrex GT5.0-NA-240 Owner's Manual

Grid tie solar inverter
Table of Contents

Advertisement

Monitoring the Inverter
Viewing more
information

Front Panel Display Screens and What They Mean

Startup Mode

5–2
Additional screens of information about the performance of the GT Inverter can be
displayed by tapping the inverter front panel. This causes the LCD to cycle
through a series of information screens in Normal Operation, Offline or Fault
modes. These are described in detail in the following section, "Front Panel
Display Screens and What They Mean".
The front panel display shows different message screens during different modes of
operation (Startup, Normal, Offline, and Fault). All single units display a basic set
of message screens; multiple unit systems display additional screens in Normal
Operation and Offline modes.
In addition there are Special message screens that may appear in any operational
mode. All these message screens are described in more detail in the following
tables.
During startup, the GT Inverter displays several message screens on its front panel
LCD. These screens appear in the following order (Table 5-1).
Table 5-1 Startup Screens on GT Inverter Front Panel Display
Display
Power
5000W
NA-240/208V
Flash = 03.01
..ROM = 03.00
Vh=
266V
Clr t < 1.00s
Vl=
177V
Clr t < 2.00s
Duration
5 seconds Startup message 1: Maximum output power and
Region-nominal output voltage
5 seconds Startup message 2: Model and revision numbers
for Flash and ROM memory on the GT Inverter.
The ROM revision number applies to the
protection processor.
3 seconds Vh: phase-to-phase (rms) high threshold voltage
setting, the threshold at which the inverter
disconnects itself from the power grid when
abnormally high phase-to-phase AC voltage is
detected.*
Clr t: clear time.†
3 seconds Vl: phase-to-phase (rms) low threshold voltage
setting, the threshold at which the inverter
disconnects itself from the power grid when
abnormally low phase-to-phase AC voltage is
detected.
Clr t: clear time.