Operating in Inverter Mode
Inverter Mode Setting is OFF
When the Freedom HF's Inverter function is turned off ("1n0") and
the AC source is outside the operating range or is disconnected,
the Freedom HF will not switch to invert mode. This means that
even if the Inverter Power button is pressed to try and turn inverter
function on, there will be no power coming from the battery to the
AC output terminals. Therefore, any appliance connected to the
AC output terminals will not operate.
Energy Saver 25-hour Automatic
Shut Off
During invert mode, a 25-hour countdown is initiated when the AC
load drops to less than approximately 80 watts and remains below
this level. After 25 hours the inverter automatically shuts off to
reduce battery discharge and preserve battery life.
NOTE: The feature is available only for Freedom HF 1500 (PN: 806-1544) and Freedom HF 1800 T (PNs: 806-
1840-01, 806-1840-03, and 806-1840-04).
32
Status LED During Inverter Mode
The following summarizes the behavior of the Status LED during
Inverter mode.
Table 2Status LED during Inverter Mode
Status
Display Screen
LED
Solid
12.8
YELLOW
(where 12.8 is an
example of battery
voltage)
11
(where 11 is an
example of current)
0.85
(where 0.85 is an
example of output
power in Kilowatts)
E05 through e07
Condition
Select button is pressed to display Input Battery
Voltage.
The Input Battery Voltage LED lights up.
Value in display screen is shown as Volts.
Select button is pressed to display Input
Current.
The Input Current LED lights up.
Value in display screen is shown as Amps.
Select button is pressed to display Output
Power.
The Output Power LED lights up.
Value in display screen is shown as Kilowatts.
Warning condition detected while AC output
power is still available.
See Error codes displayed on the Display
Panel screen on page 46.
Freedom HF Owner's Guide