4.2.39 Intelligent input terminal setting
You can assign the functions described below to intelligent input
terminals [1] to [8]. To assign the desired functions to the
terminals, specify the desired data listed in the table below for
terminal settings "C001" to "C008". For example, "C001"
corresponds to intelligent input terminal [1].
You can select the a-contact or b-contact input for individual intelligent input terminals.
You can assign one function only to an intelligent input terminal. If you have attempted to assign a function
to two or more intelligent input terminals, the function is assigned to only the terminal to which you have
last attempted assignment. Function data "NO" (no assign) is assigned to other terminals, and those
terminals are ineffective in terms of functions.
After assigning the desired functions to intelligent input terminals [1] to [8], confirm that the assigned
functions have been stored on the inverter.
Function code
Data
01
RV: Reverse RUN command
02
CF1: Multispeed 1 setting (binary operation)
03
CF2: Multispeed 2 setting (binary operation)
04
CF3: Multispeed 3 setting (binary operation)
05
CF4: Multispeed 4 setting (binary operation)
06
JG: Jogging
07
DB: External DC braking
08
SET: Set 2nd motor data
09
2CH: 2-stage acceleration/deceleration
11
FRS: Free-run stop
12
EXT: External trip
13
USP: Unattended start protection
14
CS: Commercial power source enable
15
SFT: Software lock (control circuit terminal block) Software lock function
16
AT: Analog input voltage/current select
17
SET3: 3rd motor control
18
RS: Reset
20
STA: Starting by 3-wire input
21
STP: Stopping by 3-wire input
22
F/R: Forward/reverse switching by 3-wire input
23
PID: PID disable
24
PIDC: PID reset
C001 to C008
26
CAS: Control gain setting
27
UP: Remote control UP function
28
DWN: Remote control DOWN function
29
DWN: Remote control data clearing
31
OPE: Forcible operation
32
SF1: Multispeed 1 setting (bit operation)
33
SF2: Multispeed 2 setting (bit operation)
34
SF3: Multispeed 3 setting (bit operation)
35
SF4: Multispeed 4 setting (bit operation)
36
SF5: Multispeed 5 setting (bit operation)
37
SF6: Multispeed 6 setting (bit operation)
38
SF7: Multispeed 7 setting (bit operation)
39
OLR: Overload restriction selection
40
TL: Torque limit enable
41
TRQ1: Torque limit selection bit 1
42
TRQ2: Torque limit selection bit 2
43
PPI: P/PI mode selection
44
BOK: Braking confirmation
45
ORT: Orientation
46
LAC: LAD cancellation
47
PCLR: Clearance of position deviation
48
STAT: Pulse train position command input enable
50
ADD: Trigger for frequency addition (A145)
Description
4 - 46
Chapter 4 Explanation of Functions
Related code
C001 to C008: Terminal [1] to [8] functions
Reference item
Operation command
Multispeed operation function
Jogging operation function
DC braking (external DC braking) function
2nd/3rd motor control function
2-stage acceleration/deceleration function
Free-run stop function
External trip function
Unattended start protection function
Commercial power supply switching function
External analog input setting function
2nd/3rd motor control function
Reset
3-wire input function
PID function
Control gain switching function
Remote control (UP/DWN) function
Forcible-operation function
Multispeed operation function
Overload restriction function
Torque limitation function
P/PI switching function
Brake control function
Orientation function
LAD cancellation function
V2 control mode selection function
Frequency addition function
Page
4-47
4-49
4-20
4-50
4-30
4-52
4-57
4-56
4-53
4-51
4-12
4-50
4-54
4-57
4-26
4-58
4-56
4-51
4-47
4-39
4-92
4-58
4-81
4-96
4-10
4-96
4-14

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents