7.1 Specifications
(1) Specifications of the 200 V class model
Model name (type name)
SJ700-XXXLFF,LFU
Max. applicable motor
capacity (4-pole) (kW)
Rated capacity
200V
(kVA)
240V
Rated input AC voltage
Rated output voltage
Rated output current (A)
Regenerative braking
Minimum connectable
resistance (Ω)
Approx. weight (kg)
(2)
Specifications of the 400 V class model
Model name (type name)
SJ700-XXXXHFF,HFEF,HFUF
Max. applicable motor
capacity (4-pole) (kW)
400V
Rated capacity
(kVA)
480V
Rated input AC voltage
Rated output voltage
Rated output current (A)
Regenerative braking
Minimum connectable
resistance (Ω)
Approx. weight (kg)
(3) Common specifications of 200 V class and 400 V class models
Model name (type name)
SJ700-XXXXXFF,FEF,FUF
Protective structure
Control system
Output frequency range
Frequency accuracy
Frequency setting
resolution
Voltage/frequency
characteristic
Speed fluctuation
Rated overload current
Acceleration/deceleration
time
Starting torque
DC braking
055
075
110
5.5
7.5
11
8.3
11.0
15.9
9.9
13.3
19.1
Three-phase (3-wire), 200 to 240 V (+10%, -15%), 50/60 Hz (±5%)
Three-phase (3-wire), 200 to 240 V (corresponding to the input voltage)
24
32
46
Internal BRD circuit (external discharge resistor)
17
17
17
6
6
6
055
075
110
5.5
7.5
11
9.7
13.1
17.3
11.6
15.8
20.7
Three-phase (3-wire), 380 to 480 V (+10%, -15%), 50/60 Hz (±5%)
Three-phase (3-wire), 380 to 480 V (corresponding to the input voltage)
14
19
25
Internal BRD circuit (external discharge resistor)
70
50
50
6
6
6
055
075
110
L/H
L/H
L/H
IP20
Sine-wave PWM control
0.1 to 400 Hz
Within ±0.01% of the maximum output frequency for digital input, within ±0.2% of maximum frequency
for digital input (at 25±10°C)
Digital input: 0.01 Hz
Analog input: Maximum output frequency/4000
(O terminal input: 12 bits/0 to +10 V, O2 terminal input: 12 bits/-10 to +10 V, OI terminal input: 12 bits/0
to +20 mA)
V/f characteristic variable with the base frequency set between 30 to 400 Hz, constant- or
reduced-torque V/f control, sensorless vector control, 0Hz-range sensorless vector control
±0.5% (with sensorless vector control or 0Hz-range sensorless vector control)
150%/60 seconds, 200%/3 seconds
0.01 to 3,600.0 seconds (in linear or curved pattern)
200%/0.3 Hz (with sensorless vector control or 0Hz-range sensorless vector control)
150%/0Hz-range torque (with 0Hz-range sensorless vector control or with a motor of capacity one
class lower than the inverter connected)
Triggered at motor start-up, when the actual motor frequency exceeds the acceleration frequency set
by a stop command, when the actual motor frequency exceeds the frequency set by a frequency
command, or by an externally input command (braking force, time, and frequency are variable).
150
185
220
15
18.5
22
22.1
26.3
32.9
26.6
31.5
39.4
64
76
95
7.5
7.5
5
14
14
14
150
185
220
15
18.5
22
22.1
26.3
33.2
26.6
31.5
39.9
32
38
48
24
24
20
14
14
14
150
185
220
L/H
L/H
L/H
7 - 1
Chapter 7 Specifications
300
370
450
30
37
45
41.9
50.2
63.0
50.2
60.2
75.6
121
145
182
External regenerative braking unit
-
22
30
30
300
370
450
30
37
45
40.1
51.9
63.0
48.2
62.3
75.6
58
75
91
External regenerative braking unit
-
22
30
30
300
370
450
L/H
L/H
L/H
550
55
76.2
91.4
220
43
550
55
77.6
93.1
112
30
550
L/H