Chapter 8 List of Data Settings
Code
Function name
H050
PI proportional gain for 1st motor
H250
PI proportional gain for 2nd motor
H051
PI integral gain for 1st motor
H251
PI integral gain for 2nd motor
P proportional gain setting for 1st
H052
motor
P proportional gain setting for 2nd
H252
motor
H060
Zero LV lmit for 1st motor
H260
Zero LV lmit for 2nd motor
Zero LV starting boost current for
H061
1st motor
Zero LV starting boost current for
H261
2nd motor
Terminal selection PI proportional
H070
gain setting
Terminal selection PI integral gain
H071
setting
Terminal selection P proportional
H072
gain setting
H073
Gain switching time
Monitored data or setting
0.0 to 999.9, 1000.
0.0 to 999.9, 1000.
0.0 to 999.9, 1000.
0.0 to 999.9, 1000.
0.01 to 10.00
0.01 to 10.00
0.0 to 100.0
0.0 to 100.0
0. to 50. (%)
0. to 50. (%)
0.0 to 999.9, 1000.
0.0 to 999.9, 1000.
0.00 to 10.00
0. to 9999. (ms)
8 - 14
Setting
Change
Default
during
during
operation
operation
(allowed
(allowed
_FF
_FEF
_FUF
or not)
or not)
100.0
100.0
100.0
100.0
1.00
1.00
100.0
100.0
50.
50.
100.0
100.0
1.00
100.
Page