4.2.69 Cooling-fan speed drop signal (WAF)
The inverter outputs the cooling-fan speed drop (WAF) signal
when it detects that the rotation speed of its internal cooling fan
has fallen to 75% or less of the full speed.
If "01" has been selected for the cooling fan control (b092), the
inverter will not output the WAF signal, even when the cooling fan
stops.
If the WAF signal is output, check the cooling-fan cover for clogging.
You can monitor the state of the WAF signal by using the life-check monitoring function (d022).
Item
Terminal function
Alarm relay terminal function
4.2.70 Starting contact signal (FR)
The inverter outputs the starting contact (FR) signal while it is
receiving an operation command.
The FR signal is output, regardless of the setting of the run command source setting (A002).
If the forward operation (FW) and reverse operation (RV) commands are input at the same time, the
inverter stops the motor operation.
Item
Terminal function
Alarm relay terminal function
Forwa
rd operation command
Reverse operation command
St
arting contact signal (FR)
4.2.71 Heat sink overheat warning signal (OHF)
The inverter monitors the temperature of its internal heat sink,
and outputs the heat sink overheat warning (OHF) signal when
the temperature exceeds the heat sink overheat warning level
(C064).
Item
Terminal function
Alarm relay terminal function
Heat sink overheat warning level
Function code
C021 to C025
C026
Function code
C021 to C025
C026
Function code
Data or range of data
C021 to C025
C026
C064
0. to 200. (℃)
4 - 68
Chapter 4 Explanation of Functions
Related code
C021 to C025: Terminal [11] to [15] functions
C026: Alarm relay terminal function
b092: Cooling fan control
d022: Life-check monitoring
Data
40
Related code
C021 to C025: Terminal [11] to [15] functions
C026: Alarm relay terminal function
Data
41
Related code
C021 to C025: Terminal [11] to [15] functions
C026: Alarm relay terminal function
C064: Heat sink overheat warning level
OHF: Heat sink overheat warning
42
signal
Setting of the threshold
temperature at which to output the
heat sink overheat warning signal
Description
WAF: Cooling-fan speed
drop signal
Description
FR: Starting contact
signal
Description