Hitachi SJ700-2 Instruction Manual page 238

Sj700-2 series
Hide thumbs Also See for SJ700-2:
Table of Contents

Advertisement

Chapter 5 Error Codes
2) Error indications by protective functions with the digital option board (SJ-DG) mounted
Name
If timeout occurs during the communication
between the inverter and digital option board, the
SJ-DG error
inverter will shut off its output and display the error
code shown on the right.
Note: The input mode is determined by a combination of DI switch and rotary switch settings. If the option
board does not operate normally, confirm the DIP switch and rotary switch settings on the option
board.
Functions of the DIP and rotary switches on the digital option board (SJ-DG)
Rotary
DIP switch
switch
Type
Code
Switch No.
Code for
setting
1
2
OFF: PAC
(batch
input
mode)
OFF: BIN
(binary
input)/
ON: BCD
(BCD
input)
ON: DIV
(divided-inp
ut mode)
: Input mode specified by switch settings
Note: For details, refer to the instruction manual for the option board.
Description
Frequency setting
0.01 Hz
0.1 Hz
0
1
2
3
4
5
6
0
1
2
3
4
5
6
7
8
9
A
B
Acceleration/
deceleration time setting
Data resolution
1 Hz
Rate
0.01 sec
5 - 6
Display on digital
remote operator
operator
OP1-0
Torque limit
setting
0.1 sec
1 sec
1%
Display on
ERR1***
OP2-0
Position
setting
1 pulse

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents