Hitachi SJ700-2 Instruction Manual page 229

Sj700-2 series
Hide thumbs Also See for SJ700-2:
Table of Contents

Advertisement

Register
Function name
No.
Electronic thermal setting
(calculated within the inverter
230Ch
from current output), 2nd
motor
Electronic thermal
230Dh
characteristic, 2nd motor
230Eh to
(Reserved)
2501h
Motor data selection, 2nd
2502h
motor
2503h
Motor capacity, 2nd motor
2504h
Motor poles setting, 2nd motor
2505h
Motor speed constant, 2nd
motor
2506h
Motor stabilization constant,
2507h
2nd motor
2508h to
(Reserved)
2514h
2515h
Motor constant R1, 2nd motor
2516h
2517h
Motor constant R2, 2nd motor
2518h
2519h
Motor constant L, 2nd motor
251Ah
251Bh
Motor constant Io, 2nd motor
251Ch
251Dh
Motor constant J, 2nd motor
251Eh
251Fh to
(Reserved)
2523h
2524h
Auto constant R1, 2nd motor
2525h
2526h
Auto constant R2, 2nd motor
2527h
2528h
Auto constant L, 2nd motor
2529h
252Ah
Auto constant Io, 2nd motor
252Bh
252Ch
Auto constant J, 2nd motor
252Dh
252Eh to
(Reserved)
253Ch
PI proportional gain for 2nd
253Dh
motor
253Eh
PI integral gain for 2nd motor
P proportional gain setting for
253Fh
2nd motor
2540h to
(Reserved)
2546h
2547h
Zero LV lmit for 2nd motor
Zero LV starting boost current
2548h
for 2nd motor
2549h to
(Reserved)
3102h
*1 The following table lists the code data for parameter "H203" (motor capacity selection):
Code data
Japan or U.S.A. mode
(b085 = 00 or 02)
EU mode (b085 = 01)
Code data
Japan or U.S.A. mode
(b085 = 00 or 02)
EU mode (b085 = 01)
Function code
R/W
b212
R/W
b213
R/W
-
-
H202
R/W
H203
R/W (*1)
H204
R/W
H205 (high)
R/W
H205 (low)
R/W
H206
R/W
-
-
H220 (high)
R/W
H220 (low)
R/W
H221 (high)
R/W
H221 (low)
R/W
H222 (high)
R/W
H222 (low)
R/W
H223 (high)
R/W
H223 (low)
R/W
H224 (high)
R/W
H224 (low)
R/W
-
-
H230 (high)
R/W
H230 (low)
R/W
H231 (high)
R/W
H231 (low)
R/W
H232 (high)
R/W
H232 (low)
R/W
H233 (high)
R/W
H233 (low)
R/W
H234 (high)
R/W
H234 (low)
R/W
-
-
H250
R/W 0 to 10000
H251
R/W 0 to 10000
H252
R/W 0 to 1000
-
-
H260
R/W 0 to 1000
H261
R/W 0 to 50
-
-
00
01
02
0.2 kW
0.4
-
0.2 kW 0.37
-
0.55
11
12
13
5.5 kW
7.5
11
5.5 kW
7.5
11
4 - 166
Chapter 4 Explanation of Functions
Monitoring and setting items Data resolution
200 to 1000
0 (reduced-torque characteristic), 1 (constant-
torque characteristic), 2 (free setting)
Inaccessible
0 (Hitachi standard data), 1 (auto-tuned data), 2
(auto-tuned data [with online auto-tuning function])
0 (2 poles), 1 (4 poles), 2 (6 poles), 3 (8 poles), 4
(10 poles)
1 to 80000
0 to 255
Inaccessible
1 to 65530
1 to 65530
1 to 65530
1 to 65530
1 to 9999000
Inaccessible
1 to 65530
1 to 65530
1 to 65530
1 to 65530
1 to 9999000
Inaccessible
Inaccessible
Inaccessible
03
04
05
06
0.75
1.5
-
-
0.75
1.1
1.5
14
15
16
17
15
18.5
22
30
15
18.5
22
30
Register
No.
0.1 [%]
-
-
0.1 [%]
-
-
0.001
1
-
0.001 [Ω]
0.001 [Ω]
0.01 [mH]
0.01 [A]
0.001
-
0.001 [Ω]
0.001 [Ω]
0.01 [mH]
0.01 [A]
0.001
-
0.1 [%]
0.1 [%]
0.01
-
0.1 [%]
1 [%]
-
07
08
09
10
2.2
3.7
-
-
2.2
3.0
-
4.0
18
19
20
21
37
45
55
75
37
45
55
75

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents