Output Connectors - Wohler AMP1-E8DA User Manual

Ampx-e8 series 2ru, dolby, multi-format, analog/ digital audio monitors
Table of Contents

Advertisement

Output Connectors

If you are connecting downstream equipment to the AES loop-
through outputs of this connector, then you should unterminate this
connector. If you are not connecting downstream equipment, then
you should terminate the selected input connector. Refer to
Terminating/Unterminating Inputs on page 40
3G/HD/SD-SDI In (1 and 2, BNC-F): These inputs accept SDI video
signals for the 3G models.
Note:
The DA model does not feature SDI capability.
If Dolby E and Dolby D (AC-3) audio signals are encoded within an
SDI bitstream selected in
embedded and de-coded for monitoring through the unit and for
output through the Decoded Dolby E/AC-3 Out connectors. PCM
signals embedded within the SDI bitstream are also de-embedded
for monitoring through the unit. See
for details.
Metered Analog (DB-25): This connector outputs the analog signal
that is displayed on the front panel level meters. The pin-out
information for this DB-25 is identical to that of the
connector. See
Figure 2–8 on page
Note:
The Analog Output Preference (AOutputPref) entry
within the
outputs the speaker Assign when a DM1, DM2, or DM3
downmix selection is enabled. The default setting is
Downmix, which outputs the metered signal with
individual channel scaling (gain settings) intact as
determined by the selected downmix (DM1, DM2, or
DM3). If
channels are output from these connectors at unity gain.
See
Analog Output Preference Mode on page 58
information on how to set this parameter.
3G/HD/SD-SDI Re-Clocked Out (BNC): This connector outputs a
re-clocked copy of the SDI signal fed to the SDI input connector
selected for monitoring. When an SDI input is not selected for
monitoring in the unit,
this output by default.
© 2 0 1 1 Woh l er Te c h n o l o g i es , I n c . A ll r i g h t s r e se r ve d .
C h a p t e r 2
R e a r P a n e l C o n n e c t o r s
Dolby Decode Mode
Chapter
15.
Setup Menu
determines how this connector
is selected, then all metered
Discrete
SDI In 2
will be reclocked and connected to
8 2 1 0 1 6 :
System Overview
for details.
, they will be de-
5:
Dolby on page 49
Analog Input
for
A M P x- E 8 S e r i e s U s e r G u i d e
17

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Amp2-e8daAmp1-e8mda-3gAmp2-e8mda-3gAmp e8 seriesAmp1-e8-da

Table of Contents