Amp2-am series 2u analog monitor speaker unit with two vu or ppm mechanical level meters, two balanced and two unbalanced inputs, two loop-thru outputs, and phase indication
1u stereo audio speaker monitors with two or optional four analog audio inputs, stereo analog outputs, and optional dual 10-segment level meters and phase indication amp1a series (22 pages)
AMP2-AM Series (AMP2-AMVU and AMP2-AMPPM) 2U Analog Monitor Speaker Unit with Two VU or PPM Mechanical Level Meters, Two Balanced and Two Unbalanced Inputs, Two Loop-Thru Outputs, and Phase Indication Document P/N 821540 Rev. A User Manual CONTENTS Title and Contents .............
Introduction Congratulations on your selection of a Wohler Technologies product. We are confident it represents the best performance and value available, and we guarantee your satisfaction with it. If you have questions or comments you may contact us at: Wohler Technologies, Inc.
Page 4
The AMP2-AMVU model utilizes mechanical meters exhibiting VU ballistic characteristics while the AMP2-AMPPM model utilizes mechanical meters exhibiting PPM ballistic characteristics with a choice of EBU or BBC scales..
MVU Level Gain Calibration: Level Gain Calibration adjustment for the AMP2-AMVU is done by adjusting two trim pots (P1 and P2) on the level meter driver PCB (919036V). The units top cover must be removed to access this PCB, which is mounted in the center of the chassis bottom.