C h a p t e r 2
S y s te m O v e rv i e w
R e a r P a n e l C o n n e ct o r s
Programming and Remote Access Connectors
8 2 1 0 1 6 :
A M P x- E 8 S e r i e s U s er G u i d e
20
© 2 0 1 1 Wo h l e r Tec h n o l o g i e s , I n c. A l l r i g h t s r e s er ve d .
RS-232 Connectors
Figure 2–14
•
RS-232 A (DB-9): This connector is used for downloading
programming, setup, and diagnostic information into and out of the
main board.
•
RS-232 B (DB-9): This connector is used for downloading
programming, setup, and diagnostic information into and out of the
Dolby E card.
•
RS-232 C (DB-9) (not available on the DA models): This connector
is used for downloading programming, setup, and diagnostic
information into and out of the 3G card.
Remote Connector
Remote (DB-9) (2RU models only): When equipped with the optional
RC4-4 interface board and configured in software, this connector (not
RS-232) provides limited remote control and status reporting with GPI/
O signals: four inputs (Controls 1 through 4) and four outputs (Status 1
through 4) as shown in
Table 2–5
RC4-4 Connector Interface Pin Out
Pin
1
Type Select 1, Status Output
2
Type Select 0, Status Output
3
Common, Ground
4
Type Select 0, Control Input
5
Channel Select 0, Status Output
6
Channel Select 1, Status Output
7
Channel Select 0, Control Input
RS-232 Pin-Out
Table 2–5
below.
Description