Wohler AMP2-VSD User Manual

Wohler AMP2-VSD User Manual

2u digital audio speaker monitor

Advertisement

Quick Links

AMP2-VSD and AMP2-VSDA
2U Digital Audio Speaker Monitor
With SDI Input and Output on BNC, Two AES Inputs on
BNC and XLR, Two AES Outputs From SDI on BNC, Four
Analog Inputs on XLR (-VSDA Only), Two Selected Analog
Stereo Outs on XLR, Four High-Res 53-Segment Level Meters,
Summable Channel Assignment, and Phase Indication
Title and Contents ........................................................................
Important Safety Instructions and Introduction .................................................
Description and Features ...........................................................................
Applications and Specifications ..................................................................
Installation ...............................................................................................
Section 2: Operation ...................................................................
Front Panel Features ................................................................................
Rear Panel Features ..................................................................................
Audio Amplifier and Speaker Configuration ................................................
Balance Control Characteristics .................................................................
Section 3: Technical Information .........................................
General Technical Observations .................................................................
SDI to AES Converter Module (919096) ..................................................
AES to Analog Converter Module PCB (919050) ......................................
AES Error Jumper Locations (919050) ......................................................
Level Meter DIP Switch Locations ............................................................
Level Meter Alternative Scales ..................................................................
Level Meter Phase Correlation Featrure .....................................................
AMP2-VSD Interconnect Block Diagram ..................................................
AMP2-VSDA Interconnect Block Diagram ...............................................
© 2004 Wohler Technologies Inc. ALL rights reserved
Document P/N 821581 Rev-B
User Manual
CONTENTS
1
2
3
4
5
6
7
8
12
16
16
17
18
19
20
21
22
23
24
25
26
26
27
28
1

Advertisement

Table of Contents
loading

Summary of Contents for Wohler AMP2-VSD

  • Page 1: Table Of Contents

    Level Meter Internal 10-Position DIP Switch Settings ......... Level Meter DIP Switch Locations ............Level Meter Alternative Scales ..............Level Meter Phase Correlation Featrure ............. AMP2-VSD Interconnect Block Diagram ..........AMP2-VSDA Interconnect Block Diagram ..........© 2004 Wohler Technologies Inc. ALL rights reserved...
  • Page 2 Introduction Congratulations on your selection of a Wohler Technologies product. We are confident it represents the best performance and value available, and we guarantee your satisfaction with it. If you have questions or comments you may contact us at: Wohler Technologies, Inc.
  • Page 3: Specifications

    Specifications Installation Congratulations on your selection of a Wohler Technologies AMP2-VSD or AMP2-VSDA audio monitor unit. We are confident it represents the best performance and value available, and we guarantee your satisfaction with it. If you have questions or comments you may contact us at:...
  • Page 4: Section 1: Features, Specs, And Installation

    AMP2-VSDA Front Panel Description The AMP2-VSD and AMP2-VSDA are monitors capable of audibly monitoring up to four source channels through a stereo speaker system while simultaneously visually monitoring all four channels of the selected source via four high-resolution 53-segment LED bargraph level meters. Both models process digital AES and SDI audio signals, while the AMP2-VSDA is also capable of processing up to four analog audio signals.
  • Page 5 Section 1: Features, Specs, and Installation Applications The AMP2-VSD and AMP2-VSDA are ideally suited for use in VTR bays, mobile production vehicles, teleconferencing installations, multimedia systems, satellite links and cable TV facilities, and on-air radio studios. Designed and manufactured in the U.S., both models are backed by a strong warranty and a satisfaction guaranteed return policy.
  • Page 6: Installation

    AMP2-VSD and AMP2-VSDA User Manual P/N 821581 Rev-B Section 1: Features, Specs, and Installation Installation Mounting The unit should be mounted where convenient for operating persons, ideally at approximately ear/eye level for best high frequency response and visual observation of the level meters. Its superior magnetic shielding eliminates concerns about locating it adjacent to most types of CRT monitors, including even high-resolution color monitors.
  • Page 7: Section 2: Operation

    AMP2-VSD and AMP2-VSDA User Manual P/N 821581 Rev-B Section 2 Operation Front Panel Features Rear Panel Features Audio Amplifier and Speaker Configuration Balance Control Characteristics © 2004 Wohler Technologies Inc. ALL rights reserved...
  • Page 8 Section 2: Operation Front Panel Features Please refer to Figure-2a on the facing page to familiarize yourself with the front panel features of the AMP2-VSD and AMP2-VSDA units. The following sections describe these features and are referenced, by number, to Figure-2a.
  • Page 9 AMP2-VSD and AMP2-VSDA User Manual P/N 821581 Rev-B Section 2: Operation AMP2-VSDA AMP2-VSD Figure-2a: Front Panel Features © 2004 Wohler Technologies Inc. ALL rights reserved...
  • Page 10 AMP2-VSD and AMP2-VSDA User Manual P/N 821581 Rev-B Section 2: Operation Front Panel Features (Continued) Phase Indication LEDs These three LEDs indicate the instantaneous and average phase (polarity) conditions between the two signals in the channel pair (or downmix) assigned to the left and right speaker channels. The two smaller LEDs labeled FAST show instantaneous phase relationships in the signal.
  • Page 11 AMP2-VSD and AMP2-VSDA User Manual P/N 821581 Rev-B Section 2: Operation AMP2-VSDA AMP2-VSD Figure-2a: Front Panel Features © 2004 Wohler Technologies Inc. ALL rights reserved...
  • Page 12 Section 2: Operation Rear Panel Features Please refer to Figure-2b on the facing page to familiarize yourself with the rear panel features of the AMP2-VSD and AMP2- VSDA unit. The following sections describe these features and are referenced, by letter, to Figure-2b.
  • Page 13 AMP2-VSD and AMP2-VSDA User Manual P/N 821581 Rev-B Section 2: Operation AMP2-VSDA AMP2-VSD Figure-2b: Rear Panel Features © 2004 Wohler Technologies Inc. ALL rights reserved...
  • Page 14 Section 2: Operation AMP2-VSD and AMP2-VSDA User Manual P/N 821581 Rev-B Rear Panel Features (Continued) AES Input Termination DIP Switch This 4-position DIP switch module is used to set the termination characteristics for the AES inputs. In the event that either of the two AES input channels is fed to downstream equipment, the associated DIP switch section (section 1 = AES IN 1 and section 3 = AES IN 2) must be placed in the UP (Unterminated) position.
  • Page 15 Section 2: Operation AMP2-VSD and AMP2-VSDA User Manual P/N 821581 Rev-B AMP2-VSDA AMP2-VSD Figure-2b: Rear Panel Features © 2004 Wohler Technologies Inc. ALL rights reserved...
  • Page 16 AMP2-VSD and AMP2-VSDA User Manual P/N 821581 Rev-B Section 2: Operation Audio Amplifier and Speaker Configuration General Description All models in the AMP Series contain high performance transducers (speakers) driven by three power amplifiers; two amplifier/ driver combinations handle midrange and high frequency information in the left and right (stereo) speaker channels, while the third amplifier channel sums the left and right channel information below the 500 Hz crossover point in the woofer (bass) speaker(s).
  • Page 17: Section 3: Technical Information

    AMP2-VSD and AMP2-VSDA User Manual P/N 821581 Rev-B Section 3 Technical Information General Technical Observations SDI to AES Converter Module PCB (919096) AES to Analog Converter Module PCB (919050) AES Digital Gain Fine Adjustment (919050) AES Error Jumper Locations (919050)
  • Page 18 AMP2-VSD and AMP2-VSDA User Manual P/N 821581 Rev-B Section 3: Technical Information General Technical Observations General Mechanical Observations Elimination of cabinet and component sympathetic vibrations (resonances) requires considerable attention to mechanical details. Because of this, and the physical constraints of the speaker’s acoustic enclosures, even minor changes to any of the mechanical details of the unit can seriously impair its acoustic performance.
  • Page 19 SDI to AES Converter Module PCB (919096) The 919096 (Serial Digital to AES Converter) module allows selected Wohler Technologies audio monitoring systems to be connected directly to a serial digital video signal containing embedded audio. Two levels of component signals (eg., D1, D5, and Digi Betacam type) are currently supported;...
  • Page 20: Aes To Analog Converter Module Pcb (919050)

    AES to Analog Converter Module PCB (919050) Description The 919050 Digi-2 (Dual Input AES to Analog Converter) module allows selected Wohler Technologies products to receive input signals in the AES or SPDIF digital audio data formats. Sampling rate and format selection are sensed and set automatically.
  • Page 21: Aes Digital Gain Calibration Fine Adjustment (919050)

    AMP2-VSD and AMP2-VSDA User Manual P/N 821581 Rev-B Section 3: Technical Information AES Digital Gain Calibration Fine Adjustment (919050) The digital gain calibration is set at the factory for +4 dB (Analog) = -20 dBFS (Digital). Three other values (+8 = -20, +6 = -9, and 0 = -18) may also be user selected via a DIP switch on the rear panel (Item I, page 14).
  • Page 22: Aes Error Jumper Locations (919050)

    AMP2-VSD and AMP2-VSDA User Manual P/N 821581 Rev-B Section 3: Technical Information AES Error Jumper Locations (919050) To disable indication of faulty AES data (and leave only indi- cation of faulty reception), place jumpers on both H14 and H18. See Item 11, page 10 for more information.
  • Page 23: Level Meter Rear Panel 6-Position Dip Switch Settings

    AMP2-VSD and AMP2-VSDA User Manual P/N 821581 Rev-B Section 3: Technical Information Level Meter Rear Panel 6-Position DIP Switch Settings Line Level (Auto) Calibration, Reference Level, and Display Mode This DIP switch sets the Line Level Calibration, Reference Level, and PPM/VU Display Mode. See the descriptions and diagram below for setting information.
  • Page 24: Level Meter Internal 10-Position Dip Switch Settings

    (a special option specified at time of order) or by removing power and then reapplying power to the unit (unplug/replug power cord). Contact Wohler Technologies for more information about this feature. Contact Wohler Technologies for information about custom scales.
  • Page 25: Level Meter Dip Switch Locations

    AMP2-VSD and AMP2-VSDA User Manual P/N 821581 Rev-B Section 3: Technical Information Level Meter DIP Switch Locations Level Meter Rear Panel 6-Position DIP Switch Module (see page 23) 919174 PCB Level Meter Internal 10-Position DIP Switch Module (see page 24)
  • Page 26: Level Meter Alternative Scales

    Switch (page 24), it is recommended that a label with the appropriate scale be applied to the front panel LED bargraph level meters. See the diagram below for scale comparison. Scale selection includes the Extended VU (standard Analog), VU, BBC, NORDIC, DIN, and Custom (not shown) scales. Contact Wohler Technologies for information about alternative scale labels. Extended VU...
  • Page 27 AMP2-VSD and AMP2-VSDA User Manual P/N 821581 Rev-B Section 3: Technical Information © 2004 Wohler Technologies Inc. ALL rights reserved...
  • Page 28 AMP2-VSD and AMP2-VSDA User Manual P/N 821581 Rev-B Section 3: Technical Information © 2004 Wohler Technologies Inc. ALL rights reserved...
  • Page 29 AMP2-VSD and AMP2-VSDA User Manual P/N 821581 Rev-B NOTE: PCB layout and schematic support documentation is available upon request. © 2004 Wohler Technologies Inc. ALL rights reserved...
  • Page 30 AMP2-VSD and AMP2-VSDA User Manual P/N 821581 Rev-B Wohler Technologies, Inc. Wohler Technologies, Inc. 31055 Huntwood Avenue 31055 Huntwood Avenue Hayward, CA 94544 Hayward, CA 94544 1-888-596-4537 Fax: (510) 870-0811 Phone: (510) 870-0810 Fax: (510) 870-0811 web: www.wohler.com US Toll-Free: 1-888-596-4537 e-mail: support@wohler.com...

This manual is also suitable for:

Amp2-vsda