Panel Pcb Assy - Brother DCP-9010CN Service Manual

Color fax/mfc
Hide thumbs Also See for DCP-9010CN:
Table of Contents

Advertisement

8.27 Panel PCB ASSY

(1) Release the three Hooks to remove the Panel PCB ASSY from the Panel unit.
(2) Turn over the Panel PCB ASSY, release the lock of the connector (CN2) by pushing it in
the direction of the arrow 2a, and disconnect the FC harness.
Note:
- After disconnecting the flat cable(s), check that each cable is not damaged at its end
or short-circuited.
- When connecting the flat cable(s), do not insert it at an angle. After insertion, check
that the cable is not at an angle.
Panel unit
Panel PCB ASSY
CN2
2c
1
Hook
Fig. 5-70
5-79
Hook
2a
FC harness
Lock
Hook
Lock
2a
2b
FC harness
Confidential