Brother DCP-9010CN Service Manual page 545

Color fax/mfc
Hide thumbs Also See for DCP-9010CN:
Table of Contents

Advertisement

WSW08 (Dial tone setting 2)
Selector No.
1
l
1st dial tone detection time length
3
4
Time-out length for 1st and 2nd dial
tone detection
5
6
Detection level of 1st dial tone and
l
busy tone before dialing
8
Note:
The WSW08 is not applicable in those countries where no dial tone detection is supported, e.g.,
USA.
- Selectors 1 through 3: 1st dial tone detection time length
Upon detection of the 1st dial tone for the time length set by these selectors, the machine starts
dialing. This setting is effective only when selectors 1 through 3 on WSW05 are set to "1,1,1."
- Selectors 4 and 5: Time-out length for 1st and 2nd dial tone detection
These selectors set the time-out length for the 1st and 2nd dial tone detection so that the machine
waits dial tone input for the specified time length and disconnects itself from the line when no dial
tone is inputted.
Function
App.1-12
Setting and Specifications
No. 1 2 3
0 0 0: 50 ms
0 0 1: 250 ms
0 1 0: 500 ms
0 1 1: 620 ms
1 0 0: 800 ms
1 0 1: 1.5 sec.
1 1 0: 2.0 sec.
1 1 1: 2.5 sec.
No. 4 5
0 0: 10 sec.
0 1: 20 sec.
1 0: 15 sec.
1 1: 30 sec.
No. 6 7 8
0 0 0: -21 dBm
0 0 1: -24 dBm
0 1 0: -27 dBm
0 1 1: -30 dBm
1 0 0: -33 dBm
1 0 1: -36 dBm
1 1 0: -39 dBm
1 1 1: -42 dBm