2.7 Checking version and system information

This section describes how to check version and system information.

2.7.1 Checking version and firmware information

You can check version and firmware information with <show system information> command.
# show system information
Current-time : Sat Apr 11 20:24:33 GMT 2009
Startup-time : Sat Apr 11 20:14:22 GMT 2009
Hardware Version : C0-07
Number of ports : 18/8
Machine Model : PY CB Eth Switch/IBP 10Gb 18/8
ROM Ver. : 2.2
ASIC Firm Ver. : 090203PL1
Firm Ver. : V01.00 NY0013 Mon Mar 9 20:40:36 JST 2009 -------8)
Startup-firmware : switch_firm
Next-boot : switch_firm
Startup-config : Thu Jan 1 00:00:00 GMT 1970 config1
Running-config : Sat Apr 11 20:14:22 GMT 2009
MAC : 001742d10960
Memory : 128MB
1) Current time
Current time is displayed
2) Startup time
Time which system booted up on is displayed
3) Hardware Version
Hardware version is displayed
4) Number of ports
The port number of 10GbE is displayed (downlink ports/uplink ports)
5) Machine Model
Machine model is displayed
6) ROM Ver.
Boot ROM version is displayed.
8) Firm Ver.
Firmware version is displayed
When switch software is operating, switch firmware version is displayed.
When IBP software is operating, IBP firmware version is displayed.
9) Startup-firmware
Current operating software mode (Switch or IBP) is displayed
10) Next-boot
Software mode in next boot is displayed
11) Startup-config
Startup config information is displayed.
PRIMERGY 10GbE Connection Blade 18/8 User Guide