PRIMERGY 10GbE Connection Blade 18/8 User Guide
SBAX2#2
Configure STP path cost in interface0/19、0/23、0/26
(config)#interface range 0/19,0/23,0/26
(config-if)#stp domain 0 cost 20000
(config-if)#stp domain 1 cost 20000
(config-if)#stp domain 2 cost 20000
Configure VLAN
(config)#interface range 0/19,0/23,0/26
(config-if)#vlan tag 100,200,300
Configure STP
(config)#stp mode mstp
(config)#stp domain 1 vlan 100,200
(config)#stp domain 2 vlan 300
(config)#stp domain 0 priority 8192
(config)#stp domain 1 priority 8192
(config)#stp domain 2 priority 12288
Save the configuraton
(config)#save
SBAX2#3
Configure STP path cost in interface0/19、0/23、0/26
(config)#interface range 0/19,0/23,0/26
(config-if)#stp domain 0 cost 20000
(config-if)#stp domain 1 cost 20000
(config-if)#stp domain 2 cost 20000
Configure VLAN
(config)#interface range 0/19,0/23,0/26
(config-if)#vlan tag 100,200,300
Configure STP
(config)#stp mode mstp
(config)#stp domain 1 vlan 100,200
(config)#stp domain 2 vlan 300
(config)#stp domain 0 priority 12288
(config)#stp domain 1 priority 12288
(config)#stp domain 2 priority 8192
Save the configuration
(config)#save