Table 2-13: Configuration > Other I/O > Outputs Tab Fields
Setting
Name
Pulse Time
Time Zones
Latching
Interlock
NetAXS-123 Access Control Unit User's Guide, Document 800-05168, Revision B
Description
Enter a unique name to identify the device.
Specifies the duration for which the device will assume
abnormal status. For example, it specifies how long a horn will
sound or a door strike will remain released. The maximum
number of hours is 1. When the hour field is blank, the
maximum number of minutes is 59. When 1 is entered in the
hour field, the maximum number of minutes is 45. The sum of
all three units comprises the pulse time. Note that you can
express seconds in tenths of a second.
Specifies two schedules:
– sets the period during which the output is
Energized
automatically energized.
– sets the period during which the
Disable Interlock
interlock, a programmed interaction between selected
inputs and outputs, will be disabled. During the selected
Time Zone this point ignores all interlock actions to it,
effectively disabling it from being a Reacting Component
during the Time Zone. Outside of the Time Zone the point
will react to interlocks as expected.
Toggles the state of the outputs between energized and
de-energized status upon every activation (code use, interlock,
or manual pulse).
Enables you to disable the interlock, or programmed interaction
between two points.
Configuring via the Web Server
Configuring Other I/O
67