Configuring via the Web Server
Configuring the System
: Use the descriptions in
Steps
Submit Changes
Table 2-3: System Tools > General Configuration > General Tab Fields
Parameter
Name
Address
Type
Upgrade Utility Port
Boot Time
Reset
22
www.honeywell.com
Table 2-3
.
Description
Unique name that identifies the panel.
Displays the address set by the panel's DIP (dual in-line
package) switches.
Note: DIP switches should be set as follows:
For the 10-position DIP switch:
Positions 1-5: ON position specify the RS-485 address.
These settings require a reboot to take effect.
Position 6: Gateway when ON, downstream when OFF. This
setting requires a reboot to take effect.
Position 7: When OFF, use user-provided IP address for
Ethernet; when ON, use default IP address for Ethernet
(192.168.1.150). When this switch changes state (OFF to
ON, ON to OFF), the effect takes place immediately. No
reboot is required.
Positions 8 and 9: RS-485-1 line termination. Both ON:
Terminated. Both OFF: Un-Terminated.
Position 10: Reserved.
For the 2-position DIP switch:
Positions 1 and 2: RS-485 2-line termination. Both ON:
Terminated. Both OFF: Un-Terminated.
See
NetAXS-123 DIP Switch
complete information on DIP switch settings.
Displays the panel type NetAXS-123.
Controls whether a gateway or downstream panel can be
updated through Ethernet from a Windows PC
(default=enabled). See www.honeywellaccess.com for
details.
Displays the time that power was applied to the panel.
Reboots the panel. A reset does not change the current
configuration in the database.
to configure the general settings, and click
Settings,
page 153
for more