8. If you want to change an existing card format's data layout, double-click the
NetAXS-123 Access Control Unit User's Guide, Document 800-05168, Revision B
Table 2-7: Configuration > Doors: > 1 > Reader A > Card Format Fields
Setting
Site Code A
Site Code B
Site Code C
Site Code D
format's name on the list of existing formats to display the Card Format Data
Layout screen. Use the descriptions in the table above to edit the layout's
fields. Then, click
Update
save with a different format name) to save the edited format. To return to the
default settings for the card format, click
.
Delete
Configuring via the Web Server
Description
Lists where on the card the Site Code A is listed. Consult
the card manufacturer for detail on the card detail.
Start Bit
– First bit in the card where the card's Site Code
begins.
– Number of bits to the right of the start bit,
Num Bits
including the start bit, that comprise the Site Code.
Most card formats require only Site Code A.
Lists where on the card the Site Code B is listed. Consult
the card manufacturer for detail on the card detail.
Start Bit
– First bit in the card where the card's Site Code
begins.
– Number of bits to the right of the start bit,
Num Bits
including the start bit, that comprise the Site Code.
Most card formats require only Site Code A.
Lists where on the card the Site Code C is listed. Consult
the card manufacturer for detail on the card detail.
Start Bit
– First bit in the card where the card's Site Code
begins.
– Number of bits to the right of the start bit,
Num Bits
including the start bit, that comprise the Site Code.
Most card formats require only Site Code A.
Lists where on the card the Site Code D is listed. Consult
the card manufacturer for detail on the card detail.
– First bit in the card where the card's Site Code
Start Bit
begins.
– Number of bits to the right of the start bit,
Num Bits
including the start bit, that comprise the Site Code.
Most card formats require only Site Code A.
(to save in the format's current name) or
. To delete the card format, click
Reset
Configuring the Doors
(to
Save as
45