Table 2-5: Configuration > Doors > 1 > Reader A Tab Fields (continued)
Setting
Description
Access Mode
Escort
(continued)
entry by an employee card holder. When this mode is
enabled, the reader LED changes color four times per
second (usually red then green) and employees must be
accompanied by a supervisor to gain entry. When the
supervisor presents his card, the LED goes solid red for 10
seconds, pending an employee credential. When the
employee credential is swiped within 10 seconds of the
supervisor card swipe, the door opens to admit the
employee and the LED returns to rapid flashing. If the time
expires and there is no employee credential swipe, the LED
returns to rapid flashing and the reader returns to escort
mode. A supervisor can gain entry by simply swiping the
card twice. Unlike Supervisor mode, the Escort mode when
active cannot be disabled during its time zone; a supervisor
is required for all employee access during Escort mode time
zone. VIP cards do not need a supervisor card to gain
access.
– A mode that requires a supervisor escort to allow