L (Time Zone) Command - Honeywell NetAXS-123 User Manual

Access control unit
Hide thumbs Also See for NetAXS-123:
Table of Contents

Advertisement

Using WIN-PAK with NetAXS-123
Standalone Commands

3.8.3 L (Time Zone) Command

_L=pn_tz_h1:m1-h2:m2_days<CR>
Variables:
pn = panel number (1-31)
tz = time zone number (1-63 (127))
h1 = start time zone: hours (00-23) (Military time)
m1 = start time zone: minutes (00-59)
h2 = end time zone: hours (00-23) (Military time)
m2 = end time zone: minutes (00-59)
days = days of week, valid values as listed below:
1 = Monday
2 = Tuesday
3 = Wednesday
4 = Thursday
5 = Friday
6 = Saturday
7 = Sunday
0 = Holiday 1
8 = Holiday 2
9 = Holiday 3
:
Notes
WIN-PAK only supports 0-63 natively, with 1-63 being definable.
The earliest time possible is 00:00; the latest time possible is 23:59. A single time
zone cannot be made to span midnight; this can be simulated through extended
commands. For more information, contact Technical Support.
Holiday 2 and Holiday 3 are not supported by current WIN-PAK.
Example #1:
_L=5_10_08:00-17:00_1_2_3_4_5<CR>
This command would configure panel 5 to add a time zone entry to time zone number
10 ranging from 8 am to 5 pm and would be valid during Monday, Tuesday,
Wednesday, Thursday, and Friday.
Example #2:
_D=25_45_16:00-23:59_0_6_7_8_9<CR>
This command would configure panel 25 to add a time zone entry to time zone
number 45 ranging from 4 pm to 11:59 pm and would be valid during Saturday,
Sunday, Holiday 1, Holiday 2, and Holiday 3.