3.3.4 Operation from the control panel

This section describes how to set the start and stop control modes, as well as torque commands
from the control panel.
Setting the start and stop modes
To make it possible to start/stop from the operating panel in torque control mode,
[Set the basic parameter (operation command mode selection) at (operating
panel).]
[Setting procedure]
Key operated LED display
MON
ENT
ENT
Selecting a torque command mode
To make it possible to set a torque command from the operating panel in torque control mode,
[Set the extended parameter  (torque command selection) at  (Control panel).]
[Setting procedure]
Key operated LED display
MON
ENT
ENT
ENT
Torque command
See the next page for the setting procedure.
Title

The operation frequency is displayed. (Make this setting when
the motor is out of operation.)(If the monitor display mode

setting parameter
Press the [MON] key to call up the first basic parameter 

(Automatic acceleration/deceleration).
Select  by pressing the

Press the Enter key to display the parameter setting. (Default
setting: )
Change the parameter setting to  (Operating panel input
enabled) by pressing
Press the Enter key to save the change. Then,  and
 
the set value are displayed alternately.
The operation frequency is displayed. (Make this setting when
the motor is out of operation.)(If the monitor display mode

setting parameter
Press the [MON] key to call up the first basic

parameter  (Automatic acceleration/deceleration).
Select  by pressing the

Press the Enter key to display the first parameter

.
Select  (Torque reference selection) by pressing the

Press the Enter key to display the parameter setting.
Select  (Panel input) by pressing
Press the Enter key to save the change. Then, 
 
and the set value are displayed alternately.
Function
Control panel torque command
Operation
is set at  [Running frequency])

key.
Operation
is set at  [Running frequency])

key.
Adjustment range
  [%]
C-14
[Torque control mode]
or
key.
or
key.
key.
Default setting