Example of parameter setting
Follow the procedure below to set a parameter.
(Example of setting: Changing the positive torque limit parameter from 150 to 100)
Key operated
MON
ENT
ENT
ENT
If you feel puzzled about what to do next during this operation, press the Monitor key
several times to return to the step and follow the above steps all over again.
4.1.3 Searching for changed parameters and changing their settings again
You can search for and display all parameters the settings of which have been changed
are different from their respective default settings, using the user parameter group .
With this parameter, you can also change their settings.
Notes on operation
The user parameter group does not display changed parameters anymore if their
settings have been returned to their respective default settings.
It may take several seconds to display changed parameters because all data stored in the
user parameter group is checked against the factory default settings.
To cancel the parameter search in process, press the
LED display
The operation frequency is displayed. (Make this setting
when the motor is out of operation.)(If the monitor
display mode setting parameter
[Running frequency])
Press the [MON] key to call up the first basic parameter
(Automatic acceleration/deceleration).
Switch to the parameter group by pressing the
Press the Enter key to activate the selected parameter
group starting at .
Press the
limit #1 .
Press the Enter key to display the parameter setting
(set value).
Change the positive torque limit parameter from
to by pressing the
Press the Enter key to save the change. Then, the
parameter code and the set value are displayed
alternately.
D-5
Operation
or
key.
key to switch to the power running torque
key.
MON
is set at
key.