Example of control panel operation
1. Set the torque command.
Follow the steps described in the
table below to set the torque
command ().
2
3.
Note)Pressing the Stop key causes the
motor to coast to a stop.
Control panel torque command 85%
Key operated
MON
ENT
ENT
ENT
MON
RUN
STOP
Starts the motor
Stops the motor
LED display
The operation frequency is displayed. (Out of operation.)
(If the monitor display mode setting parameter

set at [Running frequency])
Press the [MON] key to call up the first basic

parameter  (Automatic acceleration/deceleration)
Select  by pressing the

Press the Enter key to display the parameter setting.

Select  by pressing the

Press the Enter key to display the parameter setting.
Change the parameter setting (torque command) by

pressing
Press the Enter key to save the change. Then, 
 
and the set value are displayed alternately.
Press the Monitor key three times in a row to display the

frequency.
Press the Run key to start the motor. According to the
torque, the motor accelerates to a frequency
 
commensurate with the load.
You can change the operation frequency anytime even
during operation, by pressing

of the  setting)
Press the Stop key to stop the motor. The motor coasts
 
to a stop. (Free-run stop)
C-15
Example of typical connection
R/L1
S/L2
T/L3
Operating panel
G/E
CC
RX II RR PP
Operation
key.
Motor
U/T1
IM
V/T2
W/T3
S4
CC
ON: Torque control
OFF: Speed control
is

or
key.
key.
or
key. (Change