Selection table of separate-type options
Applicable
Voltage
Inverter
motor
class
model
[kW]
0.4
VFA7-2004PL
0.75
VFA7-2007PL
1.5
VFA7-2015PL
2.2
VFA7-2022PL
3.7
VFA7-2037PL PFL-2018S DCL-2037
5.5
VFA7-2055PL PFL-2025S DCL-2055
7.5
VFA7-2075PL
11
VFA7-2110P
15
VFA7-2150P
200V
18.5
VFA7-2185P
class
22
VFA7-2220P
30
VFA7-2300P
37
VFA7-2370P1
45
VFA7-2450P1 PFL-2200S DCL-2450 NF-3200A-MJ
55
VFA7-2550P1 PFL-2300S DCL-2550 NF-3250A-MJ
75
VFA7-2750P1 PFL-2400S DCL-2750
90
VFA7-2900P1 PFL-2600S DCL-2900
0.75
VFA7-4007PL
1.5
VFA7-4015PL
2.2
VFA7-4022PL
3.7
VFA7-4037PL
5.5
VFA7-4055PL
7.5
VFA7-4075PL
11
VFA7-4110PL
15
VFA7-4150PL
18.5
VFA7-4185P
22
VFA7-4220P
30
VFA7-4300P
400V
37
VFA7-4370P1
class
45
VFA7-4450P1
55
VFA7-4550P1
75
VFA7-4750P1
90/110
VFA7-4110KP1 PFL-4300S DCL-4110K NF-3250C-MJ
132
VFA7-4132KP1
160
VFA7-4160KP1
220
VFA7-4220KP1 PFL-4600S DCL-4220K
280
VFA7-4280KP1 PFL-4800S DCL-4280K
(*1): This filter needs to be wound 4 turns or more around with the input side power line. This filter can
be used for the output side in the same manner. For the wire whose size is 22 mm
at least 4 filters in series. Round type (Model: RC5078) is also available.
(*2): PBR3-
indicates braking resistor, PB3-
drive circuit and braking resistor(s) are built in it).
(*3): Model in square brackets is fitted with top cover.
(*4): To use 200 V-75 kW or more or 400 V-110 kW or more inverter with an external braking resistor
(DGP600 series), installation of a dynamic braking drive circuit inside the inverter is required.
(*5): There is a case that this filter is unusable depending on the type or size of the cable to be used.
(*6): About this filter for inverter models of 90 kW or more, consult with our office
(*7): These reactors are usable for each of 200V class and 400V class.
(*8): Be sure to connect DC reactor to 200V-75kW or more or 400V-110kW or more inverter. (Not
necessary for DC input.)
Radio noise reduction filter
Input AC
DC reactor
High
reactor
(DCL)
attenuation
(ACL)
type
PFL-2005S DCL-2007
PFL-2011S DCL-2022
PFL-2050S DCL-2110
NF-3050A-MJ
NF-3080A-MJ
PFL-2100S DCL-2220
NF-3100A-MJ
PFL-2150S DCL-2370 NF-3150A-MJ
NF-3200A-MJ
2 (parallel)
NF-3250A-MJ
2 (parallel)
DCL-2007
(*7)
PFL-4012S
DCL-2022
(*7)
PFL-4025S DCL-4110
PFL-4050S DCL-4220
NF-3040C-MJ
NF-3050C-MJ
NF-3060C-MJ
PFL-4100S DCL-4450
NF-3080C-MJ
NF-3100C-MJ
PFL-4150S DCL-4750 NF-3150C-MJ
NF-3200C-MJ
2 (parallel)
PFL-4400S DCL-4160K
NF-3200C-MJ
2 (parallel)
NF-3250C-MJ
2 (parallel)
NF-3250C-MJ
3 (parallel)
I-9
Braking resistor
Core
/Braking unit
Simple
type
(*2, 3, 4)
type
(*1)
PBR3-2055
PBR3-2075
RC9129
PBR3-2110
PBR3-2150
PBR3-2220
PB3-2300
RCL-M2
PB3-2550
RC9129
DGP600W-B1
(*5)
[DGP600W-C1]
PBR3-4055
PBR3-4075
PBR3-4110
RC9129
PBR3-4150
PBR3-4220
PB3-4300
PB3-4550
RCL-M4
DGP600W-B2
[DGP600W-C2]
RC9129
(*5)
DGP600W-B3
[DGP600W-C3]
DGP600W-B4
[DGP600W-C4]
indicates braking unit (dynamic braking
Motor
Motor end
noise
surge voltage
suppression
reduction
filter
filter
NRL-2220
NRL-2300
NRL-2400
MSF-4015Z
MSF-4037Z
MSF-4075Z
MSF-4150Z
MSF-4220Z
MSF-4370Z
MSF-4550Z
MSF-4750Z NRL-4155
NRL-4230
NRL-4300
NRL-4350
(*6)
NRL-4600
NRL-4550
2
or more, install

Hide quick links:

Advertisement

Table of Contents
loading