Torque Limit - Toshiba TOSVERT VF-A7 Instruction Manual

The new generation high-performance inverter 200v class 0.4- 90kw 400v class 0.75-280kw
Hide thumbs Also See for TOSVERT VF-A7:
Table of Contents

Advertisement

voltage signals
current signals

6.22 Torque limit












Function
The function is to decrease or increase the output frequency according to the load
ing condition when the motor torque reaches the limit level.
Setting a torque limit parameter at 250.0 means "Invalid".
Setting
(1) Power running /regenerative torque limit
First, you need to set the polarity of each torque limit. Set  at .
Title

a limiting the torque with internal parameters (or on communication mode)
Reverse
Torque limits can be set with the parameters  and .
[Setting of power running torque]
(Selection of power running torque limit #1) :Set at (  )
(Power running torque limit #1)
[Setting of regenerative torque]
(Selection of regenerative torque limit #1)
(Regenerative torque limit #1)
RR-CC
RX-CC
VI-CC
II-CC
Selection of power running torque limit #1
Power running torque limit #1
Selection of regenerative torque limit #1
Regenerative torque limit #1
Power running torque limit #2
Regenerative torque limit #2
Power running torque limit #3
Regenerative torque limit #3
Power running torque limit #4
Regenerative torque limit #4
Torque limit mode (polarity)
Function
Torque limit
mode (polarity)

Regenerative
Power running

0 10V
(0 250%)
0
10V
(0 250%)
0 10V
(0 250%)
4(0) 20mA (0 250%)
Adjustment range
: Power running/regenerative torque limit
: Positive/negative torque limit

Power running
Regenerative

:Set a desirable torque limit level.
:Set at (  )
:Set a desirable torque limit level.
F-45
, 
Setting value
250% torque
Forward
250% torque