Toshiba TOSVERT VF-A7 Instruction Manual page 214

The new generation high-performance inverter 200v class 0.4- 90kw 400v class 0.75-280kw
Hide thumbs Also See for TOSVERT VF-A7:
Table of Contents

Advertisement

[7] Speed/torque reference gain/bias setup (2/2)
Communi
Title
Function
cation No

0228
BIN reference point #1
0229
BIN reference point #1 frequency -  [Hz] (*1)


0230
BIN reference point #2
0231
BIN reference point #2 frequency -  [Hz] (*1)

0232
BIN reference point #1 rate

0233
BIN reference point #2 rate

0234
Pulse reference point #1


0235
Pulse reference point #1 frequency -  [Hz] (*1)
0236
Pulse reference point #2


0237
Pulse reference point #2 frequency -  [Hz] (*1)
(*1): Adjustment range is -327.68 327.67 [Hz] in case of 16-bit access.
[8] Operation frequency
Communi
Title
Function
cation No
0240
Start-up frequency


0241
Run frequency
0242
Run frequency hysteresis


0243
Stop frequency
0244
0 Hz dead band frequency

[9] DC injection braking
Communi
Title
Function
cation No

0250
DC injection braking start frequency 0.0 120.0 [Hz]
0251
DC injection braking current


0252
DC injection braking time
0253
Forward/reverse DC braking priority control 0: OFF, 1: ON


0254
Motor shaft fixing control
0255
Zero-speed stop mode selection 0: Standard(DC injection breaking), 1: 0Hz command

[10] Jogging operation
Communi
Title
Function
cation No
0260
Jog run frequency


0261
Jog stop control
(Reference section): Refer to the inverter's individual manual.
Adjustment range
-100 100 [%]
-100 100 [%]
-250 250 [%] (For torque control, etc.)
-250 250 [%] (For torque control, etc.)
-100 100 [%]
-100 100 [%]
Adjustment range
0.0 10.0 [Hz]
0.0  [Hz]
0.0 30.0 [Hz]
0.0 30.0 [Hz]
0.0 5.0 [Hz]
Adjustment range
0.0 100.0 [%]
0.0 10.0 [s]
0: Disabled, 1: Enabled
Adjustment range
0.0 20.0 [Hz]
0: Deceleration stop
1: Coast stop
2: DC injection braking stop
Sensorless vector/vector with sensor ( valid,
Min. unit (panel/
Default
Write during
Speed
communication)
setting
running
control
1/0.01
0
Enabled
/
0.01/0.01
0.0
Enabled
/
1/0.01
100
Enabled
/
0.01/0.01
80.0
Enabled
/
1/0.01
0
Enabled
/
1/0.01
100
Enabled
/
1/0.01
0
Enabled
/
0.01/0.01
0.0
Enabled
/
1/0.01
100
Enabled
/
0.01/0.01
80.0
Enabled
/
Min. unit (panel/
Default
Write during
Speed
communication)
setting
running
control
0.01/0.01
0.1
Enabled
/
0.01/0.01
0.0
Enabled
/
0.01/0.01
0.0
Enabled
/
0.01/0.01
0.0
Enabled
/
0.01/0.01
0.0
Enabled
/
Min. unit (panel/
Default
Write during
Speed
communication)
setting
running
control
0.01/0.01
0.0
Enabled
/
0.1/0.01
50.0
Enabled
/
0.1/0.01
1.0
Enabled
/
0
Enabled
/
0
Enabled
/
0
Disabled
/
Min. unit (panel/
Default
Write during
Speed
communication)
setting
running
control
0.01/0.01
0.0
Enabled
/
0
Enabled
/
:invalid)
Vector control
V/f
Reference
Torque
Position
Constant
section
control
control
/
/
/
/
Vector control
V/f
Reference
Torque
Position
Constant
section
control
control
6.7.1
6.7.2
6.7.2
6.7.1
6.7.3
Vector control
V/f
Reference
Torque
Position
Constant
section
control
control
6.8.1
6.8.1
6.8.1
6.8.1
6.8.2
6.8.3
Vector control
V/f
Reference
Torque
Position
Constant
section
control
control
6.9
6.9

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents