Toshiba TOSVERT VF-A7 Instruction Manual page 212

The new generation high-performance inverter 200v class 0.4- 90kw 400v class 0.75-280kw
Hide thumbs Also See for TOSVERT VF-A7:
Table of Contents

Advertisement

[5] Basic parameters #2
Communi
Title
Function
cation No
0170
Base frequency #2


0171
Base frequency voltage #2
0172
Manual torque boost #2


0173
Motor overload protection level #2 10 100 [%]
0174
Base frequency #3


0175
Base frequency voltage #3
0176
Manual torque boost #3


0177
Motor overload protection level #3 10 100 [%]
0178
Base frequency #4


0179
Base frequency voltage #4
0180
Manual torque boost #4


0181
Motor overload protection level #4 10 100 [%]
0182
Motor switching mode selection


0183
V/f adjustment coefficient
[6] V/f 5-point setting
Communi
Title
Function
cation No

0190
V/f 5-point setting VF1 frequency 0 400 [Hz]
0191
V/f 5-point setting VF1 voltage


0192
V/f 5-point setting VF2 frequency 0 400 [Hz]
0193
V/f 5-point setting VF2 voltage


0194
V/f 5-point setting VF3 frequency 0 400 [Hz]
0195
V/f 5-point setting VF3 voltage

0196
V/f 5-point setting VF4 frequency 0 400 [Hz]

0197
V/f 5-point setting VF4 voltage

0198
V/f 5-point setting VF5 frequency 0 400 [Hz]


0199
V/f 5-point setting VF5 voltage
(Reference section): Refer to the inverter's individual manual.
Adjustment range
25.0 400.0 [Hz]
0.0 600.0 [V]
0.0 30.0 [%]
25.0 400.0 [Hz]
0.0 600.0 [V]
0.0 30.0 [%]
25.0 400.0 [Hz]
0.0 600.0 [V]
0.0 30.0 [%]
0: standard, 1: customized
0 255
Adjustment range
0 100 [%]
0 100 [%]
0 100 [%]
0 100 [%]
0 100 [%]
Sensorless vector/vector with sensor ( valid,
Min. unit (panel/
Default
Write during
Speed
communication)
setting
running
control
0.01/0.01
60.0
Enabled
0.1/0.1
See J-28
Enabled
0.1/0.01
See J-28
Enabled
1/0.01
100.0
Enabled
0.01/0.01
60.0
Enabled
0.1/0.1
See J-28
Enabled
0.1/0.01
See J-28
Enabled
1/0.01
100
Enabled
0.01/0.01
60.0
Enabled
0.1/0.1
See J-28
Enabled
0.1/0.01
See J-28
Enabled
1/0.01
100
Enabled
-
0
Disabled
/
1/1
32
Enabled
Min. unit (panel/
Default
Write during
Speed
communication)
setting
running
control
1/1
0
Disabled
0.1/0.01
0.0
Disabled
1/1
0
Disabled
0.1/0.01
0.0
Disabled
1/1
0
Disabled
0.1/0.01
0.0
Disabled
1/1
0
Disabled
0.1/0.01
0.0
Disabled
1/1
0
Disabled
0.1/0.01
0.0
Disabled
:invalid)
Vector control
V/f
Reference
Torque
Position
Constant
section
control
control
6.4.1
6.4.1
6.4.1
6.4.1
6.4.1
6.4.1
6.4.1
6.4.1
6.4.1
6.4.1
6.4.1
6.4.1
/
/
Vector control
V/f
Reference
Torque
Position
Constant
section
control
control
6.5
6.5
6.5
6.5
6.5
6.5
6.5
6.5
6.5
6.5