Chapter 5
Encoder number:
This shows information about the number of the associated encoder. The number
corresponds to the respective camera input on the back of the unit.
Type of recording:
You can change the recording mode as required. In Ring mode recording will
continue indefinitely. When the maximum hard drive space has been reached,
the oldest recordings will be overwritten automatically. In Linear mode, recording
will continue until all the drive space has been used. Then recording will stop.
Recording data rate:
Select the desired recording rate here. The image quality increases automatically
as the data rate increases. However, a higher data rate reduces the recording
duration on the partition.
The maximum remaining recording time is recalculated after the data rate has
been set and is displayed further down the page (Remaining for recording).
Recording resolution:
Here you can change the image resolution for the recording as required.
Alarm input sources:
Here you can select the alarm sensors that should trigger an alarm. Select the
checkboxes of the alarm sources so the corresponding alarm sensors will be
monitored for alarm recording.
Note
A motion or video alarm from one camera can be used to trigger alarm
recording by another camera. The motion alarm must be configured on the
Motion Detector page (see page 98). Alarm settings are activated on the
Alarm input settings page (see page 42). The video alarm is activated on
the Camera settings page (see page 36).
Partition total size:
The displayed value shows the total space in MB occupied by the partition on the
hard drive.
VideoJet 8000
Configuration using a Web Browser
59